Gas Control Removal - Bradford White RG2F40S*(N,X) Service Manual

Atmospheric vent gas water heater
Table of Contents

Advertisement

Gas Control Testing & Replacement

Gas Control Removal

Step 1.
Move the gas control power switch to the "OFF"
position.
Step 2.
Unplug the water heater from the wall outlet.
Step 3.
Drain the water heater to a point below the gas control level.
Step 4.
Turn off the gas supply to the water heater and disconnect the gas piping
from the gas control.
Step 4.
Disconnect the pilot tube
using a 7/16" wrench and the main burner
feedline with a 3/4" wrench from the gas
control.
Step 5.
Disconnect the wire harnesses and spark igniter/
flame sense wire from the gas control.
Step 6.
Spin the gas control out of the water heater tank.
Page 22
22
Gas control power
switch
Blower (water heater)
power cord
Pilot and main feed-
lines
Gas control
Spark igniter/flame
sensor wire
Wire harnesses