Blower Replacement
Blower Removal & Installation (cont'd)
Step 3.
Disconnect the vent system from the draft hood
that is mounted on top of the blower.
Step 4.
Remove the draft hood from the blower and retain
it for use on the new blower.
Step 5.
Unplug the cord sets from the blower.
Step 6.
Remove the three blower mounting screws using a
1/4" nut driver and retain for later use.
Step 7.
Remove the blower from the top of the water
heater.
Step 8.
Clean any debris from the jacket head of the water heater.
Step 9.
Set the new blower in place using the water heater tank flue and the
screw holes in the jacket head.
Step 10
Secure the blower in place using the screws from Step 6.
Step 11.
Re-install the draft hood from Step 4.
Step 12.
Reconnect the vent system to the draft hood.
Page 20
20
Vent system
Draft hood
Blower
Cord sets
1/4" nut driver
Blower
Top of water
heater
Water heater tank flue