Remove the Blower to Gain Access to the Flue Baffle (cont'd)
Blower
Top of water
heater
Step 6.
Remove the blower from the top of the water heater.
Step 7.
Remove the flue baffle from the water heater.
Step 8.
Inspect the baffle for deterioration and missing restrictors. Clean any
scale or debris build-up. Replace with a new baffle, as necessary.
Step 9.
Reinstall the baffle into the flue. Be sure the baffle hanger tab is inserted
into the notch locations at the top of the flue.
Step 10.
Check the burner to ensure no scale has accumulated during operation.
See the Burner Cleaning Procedure on page 15, if accumulation has occurred.
Step 11.
Secure the blower in place using the screws from Step 5.
Step 12.
Reconnect the vent system to the draft hood.
Step 13.
Reconnect the cord sets from Step 4.
Step 14.
Plug the water heater into the wall outlet.
Step 15.
To resume operation, follow the instructions located on the water heater
lighting instruction label. Or, use the lighting instructions located in the water heater
installation and operating manual.
Water heater tank flue
Flue baffle