Blower Removal

Remove the Blower to Gain Access to the Flue Baffle
Step 1.
Move the gas control power switch to the "OFF"
position.
Step 2.
Unplug the water heater from the wall outlet.
Step 3.
Disconnect the vent system from the draft hood
that is mounted on top of the blower.
Step 4.
Unplug the cord sets from the blower.
Step 5.
Remove the (3) blower mounting screws using a
1/4" nut driver and retain for later use.
Page 30
30
Gas control power
switch
Blower (water heater)
power cord
Vent system
Draft hood
Blower
Cord sets
1/4" nut driver