Bradford White PV Series Service Manual

Bradford White PV Series Service Manual

Hide thumbs Also See for PV Series:

Advertisement

Manual 238-51540-00D 4/19
PV Series
Power Vent Gas Water Heaters
SERVICE
MANUAL
Troubleshooting Guide
and Instructions for Service
(To be performed ONLY by
qualified service providers)
Models Covered
by This Manual:
Through The Wall Models:
RG1PV40S*(N,X)
RG1PV50S*(N,X)
RG1PV55H*(N,X)
RG2PV40T*(N,X)
RG2PV50H*(N,X)
RG2PV50T*(N,X)
RG2PV75H*(N,X)
RG2PV60T*(N,X)
LG1PV55H78*(N,X)
LG2PV50H65*(N,X)
LG2PV75H76*(N,X)
(*) Denotes Warranty Years
Save this manual for future reference

Advertisement

Table of Contents
loading

Summary of Contents for Bradford White PV Series

  • Page 1 PV Series Power Vent Gas Water Heaters SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered by This Manual: Through The Wall Models: RG1PV40S*(N,X) RG1PV50S*(N,X) RG1PV55H*(N,X) RG2PV40T*(N,X) RG2PV50H*(N,X) RG2PV50T*(N,X) RG2PV75H*(N,X) RG2PV60T*(N,X)
  • Page 2: Table Of Contents

    The Bradford White PV Series Power Vent Gas Water Heaters Through-The-Wall Gas Water Heaters Table of Contents Page PV Service Procedure Introduction ..........................4 How to Use This Manual......................5 Tools Required for Service .......................5 Specifications ..........................6 Control Timings.........................10 Sequence of Operation ......................11 Troubleshooting.........................15...
  • Page 3 PV Series WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, DANGER personal injury, or death. Do not store or use gasoline or other flammable, combustible, or corrosive vapors and liquids in FOR YOUR SAFETY the vicinity of this or any other appliance.
  • Page 4: Introduction

    PV Series Introduction The new Bradford White RG1PV & RG2PV water heaters are designed to provide reliable performance with enhanced standard features. New design features include reliable spark to pilot ignition system, enhanced diagnostics, simplified servicing, quiet operation, additional vent lengths, and Bradford White Defender Safety System (not available on all models).
  • Page 5: How To Use This Manual

    It is intended for this manual to be used by qualified service personnel for the primary purpose of troubleshooting and repair of the Bradford White PV Series water heaters. Understanding the sequence of operation section of this manual will contribute greatly to troubleshooting the water heater.
  • Page 6: Specifications

    PV Series Specifications Power supply Dedicated 115 VAC, 60 Hz, 15A. Gas Supply Pipe Minimum 1/2” NPT (schedule 40 black iron pipe recommended). Approved Gas Natural Gas or Propane, unit must match gas type supplied. Type 5.0” W.C. min. for Natural Gas, 11.0” W.C. min. for Propane, 14.0” W.C. maximum Gas Pressure (Natural Gas &...
  • Page 7 PV Series Specifications Vent Tables Venting Specifications for: RG1PV40S, RG2PV40T RG1PV50S, RG2PV50T 2" Diameter (5.1 cm) Vent Connector Lengths # of Maximum Straight Minimum Straight Terminating Elbows Length ft. (m) Length ft. (m) Through the Wall 45 (16.8) 2 (.6) Through the Wall 40 (15.2)
  • Page 8 PV Series Specifications Vent Tables Venting Specifications for: RG2PV50H LG2PV50H 3" Diameter (7.6 cm) Vent Connector Lengths # of Maximum Straight Minimum Straight Terminating Elbows Length ft. (m) Length ft. (m) Through the Wall 55 (16.8) 2 (.6) Through the Wall 50 (15.2)
  • Page 9 PV Series Specifications Vent Tables Venting Specifications for: RG1PV55H RG2PV75H LG1PV55H LG2PV75H 3" Diameter (7.6 cm) Vent Connector Lengths # of Maximum Straight Minimum Straight Terminating Elbows Length ft. (m) Length ft. (m) Through the Wall 45 (13.7) 2 (.6) Through the Wall 40 (12.2)
  • Page 10: Control Timings

    PV Series Specifications Control Timings Ignition State Timing Pre-purge 2 Seconds Trial for Ignition 90 Seconds Flame Stabilization Period 3 Seconds Inter-purge 15 Seconds 1.5 Seconds (2 second maximum; 1 second Flame Failure Response Time minimum.) Post-purge 15 Seconds PS Fault Delay (failed open/close)
  • Page 11: Sequence Of Operation

    PV Series Sequence of Operation Power Up Sequence 1. Start Up. Upon power up, the control runs a safe-start check with a typical start-up delay of 5 seconds. 2. Flammable Vapor. To assure no outputs are energized if the “Flammable Vapor Sensor” (for RG1PV40S, RG1PV50S, RG2PV40T, RG2PV50T, RG2PV 60T, RG2PV50H) or “Simulated Resistive Device”...
  • Page 12 PV Series Sequence of Operation Normal Heating Sequence (cont.) 7. Steady state operation. During steady state operation, the control monitors: Thermostat temperature sensor-when set point temperature is satisfied, gas valve is shut down and blower will post purge for 15 seconds. Control LED flashes a short flash once every 4 seconds (idle) status code.
  • Page 13 PV Series Sequence of Operation Abnormal Operation (cont.) times, then 3 times twice with 3 second pauses. The error self clears if the fault clears for at least 15 seconds. c. Water temperature in excess of ECO (energy cut out) limit -The gas control immediately turns off pilot &...
  • Page 14 PV Series Sequence of Operation Abnormal Operation (cont.) 5. Flame sensing fault: a. Flame lost during run-the gas control turns off pilot and main valves, runs blower for 15 seconds (inter-purge). The gas control increments the recycle count, if the recycle count has not reached its limit (4), another trial for ignition begins.
  • Page 15 PV Series PV Series Troubleshooting Observe green LED indicator on electronic gas control. Error flash codes are displayed with a three second pause before repeating. Check and repair the Observe green LED indicator on system as noted in the troubleshooting electronic gas control.
  • Page 16 PV Series Troubleshooting Service LED Status Control Status Probable Cause Procedure 1. Unstable pilot. Failed to light Six-one 2. Pilot tube blocked or restricted. flash, three pilot. Page 19 3. Oxidation build up on pilot electrode. second System auto 4. Wire damage to pilot assembly or bad pause resets.
  • Page 17: Burner Inspection, Cleaning & Replacement

    PV SERVICE PROCEDURE I PV Series Burner Operation Inspection, Cleaning and Replacement Burner Inspection At periodic intervals (every 6 months) a visual inspection should be made of the pilot and main burner for proper operation and to assure no debris is accumulating.
  • Page 18 PV SERVICE PROCEDURE I PV Series Burner Operation Inspection, Cleaning and Replacement Burner Cleaning Step 1. Position gas control power switch to the “OFF” position and unplug heater from wall outlet. Step 2. Turn off gas supply to water heater.
  • Page 19: Pilot Testing, Cleaning & Replacement

    PV Series PV SERVICE PROCEDURE II Pilot Inspection, Testing and Replacement Pilot Inspection, Testing and Replacement Step 1. Position gas control power switch to the “OFF” position and unplug heater from wall outlet. Step 2. Turn off gas supply to water heater.
  • Page 20: Pressure Switch Testing & Replacement

    PV Series PV SERVICE PROCEDURE III Pressure Switch Testing and Replacement Step 15. To resume operation, follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual. Pressure Switch Testing WARNING 115 volt potential exposure.
  • Page 21 PV Series PV SERVICE PROCEDURE III Pressure Switch Testing and Replacement Pressure Switch Replacement Step 1. Position gas control power WARNING switch to “OFF” position. 115 volt potential exposure. Use caution to avoid personal injury. Step 2. Remove the three screws (Phillip’s screw driver) from...
  • Page 22: Blower Testing & Replacement

    PV Series PV SERVICE PROCEDURE IV Blower Testing and Replacement Blower Testing WARNING 115 volt potential exposure. Use Step 1. Position gas control caution to avoid personal injury. power switch to “ON” position and adjust control to call for heat.
  • Page 23 PV Series PV SERVICE PROCEDURE IV Blower testing & Replacement Blower Removal Step 1. Position gas control power switch to “OFF” position and adjust control to call for heat. Step 2. Unplug blower power cord from wall outlet. Step 3. Disconnect vent system from exhaust adapter on top of blower.
  • Page 24: Blower Temperature Switch Testing & Replacement

    PV SERVICE PROCEDURE V PV Series Blower Temperature Switch Testing and Replacement Blower Temperature Switch WARNING 115 volt potential exposure. Use Testing caution to avoid personal injury. Position power switch on gas control to the “OFF” position. Step 1. Remove the three screws (Phillip’s...
  • Page 25 PV SERVICE PROCEDURE V PV Series Blower Temperature Switch Testing & Replacement Blower Temperature Switch WARNING 115 volt potential exposure. Use Replacement caution to avoid personal injury. Step 1. Position gas control power switch to the “OFF” position and unplug heater from wall outlet.
  • Page 26: Gas Control Testing & Replacement

    PV Series PV SERVICE PROCEDURE VI Gas Control Testing and Replacement Line Pressure The gas control is designed for a maximum line pressure of 14.0” W.C. and a minimum line pressure of 1.0” W.C. over the water heater’s rated manifold pressure (check rating plate).
  • Page 27 PV Series PV SERVICE PROCEDURE VI Gas Control Testing and Replacement ECO (Energy Cut Out) The Honeywell gas control is designed with an ECO device that will reset. To reset the gas control after an error code (4), turn the gas control knob to the “LOW”...
  • Page 28 PV Series PV SERVICE PROCEDURE VI Gas Control Testing and Replacement Gas Control Disassembly/Reassembly (cont.) Step 8. Disconnect temperature sensor from control board. Step 9. To reassemble gas control, follow the previous steps in reverse order. Once gas control is reassembled, burner assembly is reinstalled, and the gas supply line is reconnected, resume water supply to water heater.
  • Page 29 PV Series PV SERVICE PROCEDURE VI Gas Control Testing and Replacement Temperature Sensor Testing Using a multi-meter set to the ohms setting, insert one meter probe (see caution) into center wire position of temperature sensor connector, insert the second probe (see caution) into either of the outside wire positions (see photo 19).
  • Page 30 PV Series PV SERVICE PROCEDURE VI Gas Control Testing and Replacement Determine Water Temperature Inside Tank WARNING Stored water may be HOT WHEN PERFORMING THE FOLLOWING STEPS IN THIS PROCEDURE. Take necessary precaution to prevent personal injury. Note: It is important to understand once the resistance for the temperature sensor is determined from page 29, water flow through the heater should not occur.
  • Page 31 PV SERVICE PROCEDURE VII PV Series Flammable Vapor/Simulative Resistance Device Testing Gas Control Removal From Water Heater Step 1. Position the gas control power switch to the “OFF” position and unplug heater from wall outlet. Step 2. Drain the heater to a point below the gas control level.
  • Page 32 PV Series PV SERVICE PROCEDURE VI Gas Control Testing and Replacement Reinstallation of inner door assembly. Prior to reinstallation of inner door, fully inspect for the following: -Tears -Other imperfections that will inhibit proper seal -Missing material -Gasket adhesion to inner door...
  • Page 33: Flammable Vapor Device Testing And Replacement

    PV SERVICE PROCEDURE VII PV Series Flammable Vapor/Simulative Resistance Device Testing Flammable Vapor/Simulative Resistance Device Testing Step 1. Position power switch on gas control to the “OFF” position. Step 2. Disconnect flammable vapor sensor from gas control. Step 3. Using a multi-meter set to the ohms setting, check resistance of flammable vapor sensor.
  • Page 34: Safety Circuit Voltage Trace

    PV Series PV SERVICE PROCEDURE VIII Safety Circuit Voltage Trace Safety Circuit Voltage WARNING 115 volt potential exposure. Use Trace caution to avoid personal injury. NOTE: This procedure assumes a cool tank. Remove three screws (Phillips Screw driver) from control...
  • Page 35: 115 Vac Circuit Trace

    PV Series PV SERVICE PROCEDURE IX 115 VAC Trace 115 VAC Circuit Trace WARNING Step 1. Verify 115 VAC and proper polarity 115 volt potential exposure. Use at wall outlet. caution to avoid personal injury. Step 2. With unit plugged in and control power switch in the “ON”...
  • Page 36: Diptube Inspection & Replacement

    PV Series PV SERVICE PROCEDURE X Diptube Inspection & Replacement Diptube Inspection & Replacement WARNING Water Heater components and stored water may be HOT when performing the following steps in this procedure. Take necessary precaution to prevent personal injury. Step 1.
  • Page 37: Anode Inspection & Replacement

    PV Series PV SERVICE PROCEDURE XI Anode Inspection and Replacement Anode Inspection & Replacement WARNING Water Heater components and stored water may be HOT when performing the following steps in this procedure. Take necessary precaution to prevent personal injury. Step 1.
  • Page 38: Flue Baffle Inspection & Replacement

    PV Series PV SERVICE PROCEDURE XII Flue Baffle Inspection & Replacement Flue Baffle Inspection and Replacement Step 1. Position gas control power switch to the “OFF” position and unplug blower from wall outlet. Step 2. Disconnect vent system from exhaust adapter on top of blower.
  • Page 39: Inner Door Removal, Inspection & Replacement

    PV SERVICE PROCEDURE XIII PV Series Inner Door/Gasket Removal, Inspection & Replacement Inner Door Removal Procedure Step 1. Position gas control power switch to the “OFF” position. Step 2. Remove outer jacket burner access door. Step 3. Inner Door removal.
  • Page 40 PV SERVICE PROCEDURE XIII PV Series Inner Door/Gasket Removal, Inspection & Replacement Installation of Inner Door With Gasket Step 7. Clean any residual gasket residue or other debris from combustion chamber surface before installing the inner WARNING door/gasket assembly. Stripped fastener connections Step 8.
  • Page 41 PV SERVICE PROCEDURE XIII PV Series Inner Door/Gasket Removal, Inspection & Replacement Installation of Inner Door With Gasket (cont.) Step 10. Firmly place right side inner door flange against the left side inner door flange and secure with (2) ¼” hex drive screws from step 3b. DO NOT OVER TIGHTEN SCREWS.
  • Page 42 PV Series PARTS LIST ScreenLok ® Flame Arrestor Cleaning NOTICE Some models are not equipped with the ScreenLok ® Flame Arrestor. Step 1. Position Gas Control power switch to the “OFF” position. Step 2. Remove outer door. Step 3. Remove outer jacket door and inner door per service procedure XIII on page 39.
  • Page 43: Glossary Of Terms

    PV Series Glossary of Terms Frozen Exhaust Vent Terminal If an exhaust vent terminal is blocked with ice or snow due to severe conditions, the pressure switch and control will not allow the burner to operate. This will result in a three flash error code. Once the blockage is removed (through melting or other means) the controls will let the burner operate.
  • Page 44: Parts List

    PV Series PARTS LIST 31. FV Sensor 19. Main Burner 1. Blower Complete 10. Heat Trap Outlet 20. Main Burner Orifice 32. Sensor Harness (except 2. Air Mixing Inlet Cover 11. Hot Water Outlet Anode 21. Pilot Assy. 75 gal.) 3.