7 STOVE DESCRIPTION

Before reading this booklet, check the description
of the stove provided in the "Product Booklet"
enclosed.

7.1 CONTROL PANEL

The panel (Fig. 8.1) consists of a backlit LCD
display, the on button
menu buttons (
The panel is used to:
-
start and switch off the stove;
-
adjust operation;
-
set the management and maintenance
programs.
The display shows three stove operating stages:
1) OFF: means that the stove is not on or is cooling
down.
2) AWAITING FLAME: and FLAME ON indicate
that the stove is starting.
3) FIRE ON: indicates that the stove is on and is
heating.
The stove operating parameters can be set for all
three stages.
These parameters will only be active when the
stove is on, as the IGNITION and OFF stages are
managed automatically.
The stove settings can be made using three different
interfaces:
-
Scrolling: the control parameters are displayed
one at a time in sequence on the second row
of the panel.
-
Compressed: all the control parameters are
displayed at the same time on the second row
of the panel.
-
(DV\ it's possible to set only the desired room
temperature.
The stove is delivered with scrolling mode active.
The user can change mode from scrolling to
compressed or easy at any time (see par.11.33 -
"MENU TYPE").
Holding one of the two arrow buttons speeds up
the scroll rate.
7.2 OPERATING PARAMETERS
When on, the stove automatically adapts its
operation based on the set values, as shown on
the display:
PARAMETERS
Power
Fan speed
Room temp./Set temp.
44/144
USE AND & MAINTENANCE
, off button
and two
OFF
and
).
COMPRESSED
INTERFACE
"P=..."
"V=..."
".../..." (Room temp./Set temp.)
INSTALLATION MANUAL
POWER [P]: This represents the stove's heat output
or power level.
The possible values are A (automatic), 1 (minimum),
2, 3, 4, 5 (maximum).
If setting the value "A" the stove will attempt to heat
the room to the set temperature, managing the
power level completely automatically.
FAN [V]: This represents the hot air fan speed.
The possible values are A (automatic), 1 (minimum),
2, 3, 4, 5 (maximum).
If setting the value "A" the stove will manage the
fan speed automatically based on the heat output.
,Q DXWRPDWLF PRGH WKH VWRYH PD\ WHPSRUDULO\
RSHUDWH WKH IDQ DW PD[LPXP VSHHG VR DV WR UHPRYH
DQ\ H[FHVV DFFXPXODWHG KHDW LQ WKLV FDVH WKH
GLVSOD\ VKRZV ³(´ FRUUHVSRQGLQJ WR WKH IDQ VSHHG
Silent series stoves (natural convection) do not
feature the parameter relating to the air fan.
SET ROOM T.: This indicates the desired room
temperature.
The temperature value can be set in the range
between 10° and 40°C; alternatively, the following
values can be set:
L (low): the stove will operate at minimum output;
H (high): the stove will operate at the set output or
power level.
SCROLLING
INTERFACE
INTERFACE
"POWER =..."
"FAN SPEED =..."
"SET ROOM T. =..."
- cod. 00 477 0811 - 12/2011 - Palazzetti - PN - Italy