6 INSTALLATION

7KH VWRYH PXVW EH LQVWDOOHG E\ TXDOL¿HG SHUVRQQHO LQ FRPSOLDQFH ZLWK (1 

6.1 LEVELLING THE STOVE

The stove must be levelled by adjusting the feet (where featured), then checked
using a spirit level (Fig. 6.1).
A B = Spirit level
6.2 SYSTEM CONNECTIONS

6.2.1 Electrical connection

The stove is connected to the electrical system simply using the plug supplied.
The electrical connection (plug) must be easily accessible when the stove is installed.
If the power cord is damaged it must be replaced by the technical service or a
TXDOL¿HG WHFKQLFLDQ WR SUHYHQW DQ\ NLQG RI ULVN
6.2.1.1 Earth
7KH V\VWHP PXVW EH HDUWKHG DQG ¿WWHG ZLWK D UHVLGXDO FXUUHQW FLUFXLWEUHDNHU LQ
accordance with legislation in force (Fig. 6.2).
7KH ÀXH PXVW KDYH LWV RZQ HDUWK FRQQHFWLRQ
6.2.1.2 Room thermostat
The thermostat is connected to the appropriate inputs of the circuit board, as shown
in the wiring diagram in the attached "Product Manual".
6.2.1.3 5HPRWH GHYLFH RQO\ IRU PRGHOV ZKHUH ¿WWHG
The remote device is connected to inputs 1 and 2 on terminal block CN7 on the
electronic board. (only in the board where terminal block CN7 has 10 inputs)
7KH GHYLFH PXVW EH FRQ¿JXUHG DV 1250$//< 23(1 DQG KDYH DQ DGMXVWDEOH
differential.
When activated (contact opens) the stove will be switched off or on.
$IWHU LQVWDOOLQJ WKH UHPRWH GHYLFH WKH VWRYH PXVW EH VWDUWHG WKH ¿UVW WLPH IURP
the control panel.
6.2.2 &RQQHFWLRQ WR DQ DLU GLVWULEXWLRQ V\VWHP
RQO\ IRU GXFWHG PRGHOV RU SURYLGHG ZLWK GXFWLQJ NLW
Ducted models can be connected to a hot air distribution system. The pipes used
should preferably be circular with a smooth inner surface and suitably insulated to
avoid heat loss.
)RU GXFWHG VWRYHV RU PRGHOV UHDG\ WR ¿W D GXFWLQJ NLW WKDW DUH QRW FRQQHFWHG
WR D KRW DLU GLVWULEXWLRQ SLSH PDNH VXUH WKH GHÀHFWRU LV SRVLWLRQHG VR DV WR
deviate the hot air into the room where the stove is installed.
D
UCTED STOVES
8VLQJ WKH WRRO VXSSOLHG RU WKH DLU GHÀHFWRU OHYHU EDVHG RQ WKH PRGHO  WKH ÀRZ RI
hot air can be deviated from the room where the stove is installed to the ducting,
and vice-versa (Fig. 6.3).
To connect the stove to the ducting system, remove the cap by unscrewing the two
fastening screws that secure the duct closure cap on the rear of the stove (Fig. 6.4).
S
TOVES READY TO FIT A DUCTING KIT
To assemble the ducting kit see the instructions provided with the kit.
7KH ÀRZ RI KRW DLU FDQ EH GHYLDWHG IURP WKH URRP WR WKH GXFWLQJ XVLQJ WKH WRRO
VXSSOLHG ZLWK WKH NLW WR DGMXVW WKH GHÀHFWRU FRQWURO ORFDWHG RQ WKH IURQW RI WKH VWRYH
42/144
INSTALLATION
INSTALLATION MANUAL
- cod. 00 477 0811 - 12/2011 - Palazzetti - PN - Italy