Service Interval Chart
CAUTION
If you leave the key in the ignition switch, someone could accidently start the engine and seriously injure
you or other bystanders.
Remove the key from the ignition before you do any maintenance.
Lubrication
Greasing the Bearings and
Bushings
If you operate the machine under normal conditions, lubricate
all grease fittings for the bearings and bushings after every
50 hours of operation with No. 2 General Purpose Lithium
Base Grease. Lubricate bearings and bushings immediately
after every washing, regardless of the interval listed.
The grease fitting locations and quantities are as follows:
•
Pump drive shaft U-joint (3) (Figure 31)
•
Cutting unit lift arm cylinders (2 each) (Figure 32)
Figure 31
Figure 30
•
Lift arm pivots (1 each) (Figure 32)
•
Cutting unit carrier frame pivot (1 each) (Figure 33)
37
Figure 32