UN DER CO U NT E R R E F RIG E R AT IO N
Plumbing
The water supply line should be located within the shaded
area shown in the illustrations below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve between the supply and the
unit. Do not use self-piercing valves. A saddle valve kit is
avail able through an authorized Sub-Zero dealer. For local
dealer information, visit the find a showroom section of our
website, subzero.com.
IMPORTANT NOTE:
A reverse osmosis system can be used
provided there is constant water pressure as indicated in the
chart below at all times. A copper line is not recommended
for this application.
PL U M BING REQ UIREMENTS
Water Supply
Pressure (UC-24CI)
Pressure (UC-15I)
Excess Line for Connection
LEFT SIDE
OF OPENING
1
2"
15
/
"
2
(51)
(394)
3"
(76)
AREA EXTENDS 1
/
"
2
(13)
FORWARD ON FLOOR
Model UC-24CI.
POSITION OUTLET
WITH GROUNDING
PRONG ON RIGHT
1
/
" OD copper, braided stain-
4
less steel or PEX tubing
20–100 psi
(1.4–6.9 bar)
20–80 psi
(1.4–5.5 bar)
36"
(914)
8"
(203)
1
/
"
2
( 13 )
LOCATION OF
WATER LINE
TOP VIEW
Ice machine.
1
15
/
"
4
min (387)
ROUGH
OPENING WIDTH
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
4"
( 102 )
FRONT VIEW
ICE MACHINE DRAIN
Ice machine models can be ordered with or without a drain
pump. Models without a pump will drain water by gravity.
A drain must be installed.
The drain and inlet water tubes must be plumbed before
connecting to the ice machine. For the gravity drain, hori-
zontal drain lines must have a
gap will likely be required between the unit and drain.
A stand pipe with a trap below is acceptable for the drain.
24"
(610)
ROUGH
OPENING
DEPTH
1
34
/
"
2
(876)
ROUGH
OPENING
HEIGHT
5
33
/
"
8
(854)
MINIMUM
HEIGHT
REQUIRED
1
/
"
per 12"
fall. An air
(6)
(305)
4
|
subzero.com/specs
93