Sub-Zero BI-36R Design Manual page 18

Hide thumbs Also See for BI-36R:
Table of Contents

Advertisement

BUILT-I N RE FR IG E R AT ION
Electrical
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
Installation must comply with all applicable electrical codes.
E LEC T RIC AL REQUIR EMEN TS
Electrical Supply
Service
Receptacle
7"
E
(178)
6"
(152)
1
75
/
"
2
(1918)
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location.
|
18
Sub-Zero Customer Care 800.222.7820
Plumbing
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip brackets.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
to the unit at all times. A copper line is not recommended
115 VAC, 60 Hz
for this application.
15 amp
Installation must comply with all applicable plumbing codes.
3-prong grounding-type
P L UMBIN G REQU IREM EN TS
Water Supply
Pressure
Excess Line for Connection
Water supply location.
1
/
RIGHT SIDE
OF OPENING
18"
6"
(457)
(152)
3"
(76)
AREA EXTENDS 1
/
"
2
(13)
FORWARD ON FLOOR
supplied
(2.4–8.3 bar)
" OD copper, braided stainless
4
steel or PEX tubing
35–120 psi
(2.4–8.3 bar)
36"
(914)