Sub-Zero BI-36R Design Manual page 92

Hide thumbs Also See for BI-36R:
Table of Contents

Advertisement

UN DER CO U NT E R R E F RIG E R AT IO N
Electrical
The electrical supply should be located within the shaded
area shown in the illustration. For ice machine models, it is
recommended that electrical supply be placed in an adja-
cent cabinet. A separate circuit, servicing only this appli-
ance is required.
For outdoor models UC-24RO and
IMPORTANT NOTE:
UC-15I(P)O, a ground fault circuit interrupter (GFCI) is
required to reduce the risk of electrical shock. A GFCI is not
recommended for use with other undercounter models and
may cause interruption of operation.
Installation must comply with all applicable electrical codes.
LEFT SIDE
OF OPENING
1
2"
15
/
"
2
(51)
(394)
3"
(76)
FLOOR
Electrical supply location.
|
92
Sub-Zero Customer Care 800.222.7820
E L E CTRIC AL RE QU IREME N TS
Electrical Supply
Service
Receptacle
115 VAC, 60 Hz
15 amp
3-prong grounding-type