Enter a valid and unique IP address for use on the network to which the
IP ADDRESS:
projector is currently connected. This address will overwrite any previous IP address
such as the projector's factory-defined default (0.0.0.0), or one that has been assigned
by a DHCP server or other user. It takes approximately 10 seconds for the projector to
respond at its new address.
On some Ethernet networks, firewall restrictions may require that the port
PORT:
number of the projector be changed from its default of 3002. If so, enter a new valid
port number here. It is highly recommended not to use a port # below 1000, as these
ports are typically reserved for and used by common IP applications.
SUBNET MASK AND DEFAULT GATEWAY:
automatically assigned when DHCP is enabled. If a static IP is being used, the IP must
be assigned first since the projector estimates the subnet mask after the IP is entered.
The Default Gateway is an optional router device used to send and receive data
outside the subnet.
ArtNet Interface Settings
ArtNet is an Ethernet communication protocol that was developed by Artistic License.
It is used for controlling lighting/staging equipment from a lighting console or PC
application. It is based on the popular DMX512 control protocol.
This is the highest level address for a device. Typically it is set to 0.
ArtNet SUBNET:
Each packet of data is broadcasted to all devices plugged into a
ArtNet UNIVERSE:
universe (up to 512 devices/channels).
There are 512 channels per universe. This control allows you to
ArtNet CHANNEL:
specify the starting channel for this projector.
ArtNet ADVANCED MODE:
on 64 channels starting with the base channel. When advanced mode is not in use, the
projector only listens on 10 channels. You can squeeze more devices per universe
when the projector uses fewer channels.
NOTE: The additional 54 functions are not currently implemented and are reserved
for future use.
When advanced mode is enabled, the projector listens to data
ArtNet BASE CHANNEL:
on 64 consecutive channels, or 10 consecutive channels when advanced mode is not
enabled. The projector processes requests that come on either 10 or 64 consecutive
channels beginning with the 'base channel' defined here. The requests implement the
following functions:
The Subnet Mask and Default Gateway are
— SUBMENU
When this setting is enabled, each projector listens for data