Menu 4 - HEAT PUMP

4 - HEAT PUMP
* Accessory needed.
Sub-menus
For the menu
HEAT PUMP
Status information for the relevant menu can be found
on the display to the right of the menus.
plus functions
Settings applying to any installed extra
functions in the heating system.
op. mode
Activation of manual or automatic operating
mode. The status information shows the selected operat-
ing mode.
my icons
Settings regarding which icons in the heat
pump's user interface that are to appear in the slot when
the door is closed.
time & date
Setting current time and date.
language
Select the language for the display here. The
status information shows the selected language.
holiday setting
Vacation scheduling hot water and
ventilation. Status information "set" is displayed if you
set a vacation schedule but it is not active now, "active"
displays if any part of the vacation schedule is active,
otherwise it displays " off".
advanced
Setting heat pump work mode.
Menu 4.1 - plus functions
Settings for any additional functions installed in the
heating system can be made in the sub menus.
Menu 4.1.1 - pool (accessory is required)
start temp
Setting range: 5.0 - 80.0 °C
Default value: 22.0 °C
stop temperature
Setting range: 5.0 - 80.0 °C
Default value: 24.0 °C
NIBE™ F1145
4.1 - plus functions *
4.2 - op. mode
4.3 - my icons
4.4 - time & date
4.6 - language
4.7 - holiday setting
4.9 - advanced
there are several sub-menus.
Overview
4.1.1 - pool *
4.1.4 - sms *
4.9.1 - op. prioritisation
4.9.2 - auto mode setting
4.9.3 - degree minute setting
4.9.4 - factory setting user
4.9.5 - schedule blocking
Select whether the pool control is to be activated and
within what temperatures (start and stop temperature)
pool heating must occur.
When the pool temperature drops below the set start
temperature and there is no hot water or heating require-
ment, F1145 starts pool heating.
Untick "activated" to switch off the pool heating.
Caution
The start temperature cannot be set to a value
that is higher than the stop temperature.
Menu 4.1.4 - sms
Make settings for the accessory SMS 40 here.
Add the mobile numbers that are to have access to
change and receive status information from the heat
pump. Mobile numbers must include country code e.g.
+46 XXXXXXXX.
If you want to receive an SMS message in the event of
the alarm mark the box to the right of the telephone
number.
NOTE
Telephone numbers provided must be able to
receive SMS messages.
Menu 4.2 - op. mode
op. mode
Setting range: auto, manual, add. heat only
Default value: auto
functions
Setting range: compressor, addition, heating, cooling
The heat pump operating mode is usually set to "auto".
It is also possible to set the heat pump to "add. heat
only", but only when an addition is used, or "manual"
and select yourself what functions are to be permitted.