Nibe F1145 Installer Manual page 39

Hide thumbs Also See for F1145:
Table of Contents

Advertisement

Menu 1.3.2 - cooling (accessory required)
Here you can schedule when cooling is permitted in the
accommodation for up to two different time periods per
day.
If two settings conflict with each other a red exclamation
mark is displayed at the end of the line.
Schedule: The schedule to be changed is selected here.
Activated: Scheduling for the selected period is activated
here. Set times are not affected at deactivation.
Day: Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a partic-
ular day, the time for that day must be reset by setting
the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected
day for scheduling are selected here.
Adjusting: Whether or not cooling is permitted during
scheduling is set here.
TIP
If you wish to set similar scheduling for every
day of the week start by filling in "all" and then
changing the desired days.
Caution
If the stop time is before the start time it means
that the period extends past midnight.
Scheduling always starts on the date that the
start time is set for.
NIBE™ F1145
Menu 1.3.3 - ventilation (accessory required)
Increases or decreases in the ventilation to the accommod-
ation can be scheduled here for up to two time periods
per day.
If two settings conflict with each other a red exclamation
mark is displayed at the end of the line.
Schedule: The schedule to be changed is selected here.
Activated: Scheduling for the selected period is activated
here. Set times are not affected at deactivation.
Day: Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a partic-
ular day, the time for that day must be reset by setting
the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected
day for scheduling are selected here.
Adjusting: The desired fan speed is set here.
TIP
If you wish to set similar scheduling for every
day of the week start by filling in "all" and then
changing the desired days.
Caution
If the stop time is before the start time it means
that the period extends past midnight. Schedul-
ing always starts on the date that the start time
is set for.
A significant change over a longer period of time
may cause poor indoor environment and worse
operating economy.
Menu 1.9 - advanced
Menu
advanced
has orange text and is intended for the
advanced user. This menu has several sub-menus.
heating curve
Setting the heating curve slope.
external adjustment
Setting the heat curve offset when
the external contact is connected.
min. flow line temp.
Setting minimum permitted flow
line temperature.
Chapter 8 |
Control - Menus
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F1145 seriesF1145 12

Table of Contents