Menu 2 - HOT WATER

2 - HOT WATER *
* Accessory needed.
Sub-menus
This menu only appears if a water heater is docked to
the heat pump.
For the menu
HOT WATER
Status information for the relevant menu can be found
on the display to the right of the menus.
temporary lux
hot water temperature. Status information displays "off"
or what length of time of the temporary temperature in-
crease remains.
comfort mode
information displays what mode is selected, "economy",
"normal" or "luxury".
scheduling
Scheduling hot water comfort. Status inform-
ation "set" displays if any part of the schedule is active
at present, "holiday setting" displays if vacation setting
is in progress (menu 4.7), otherwise it displays "off".
advanced
Setting periodic increase in the hot water
temperature.
Menu 2.1 - temporary lux
Setting range: 3, 6 and 12 hours and mode "off"
Default value: "off"
When hot water requirement has temporarily increased
this menu can be used to select an increase in the hot
water temperature to lux mode for a selectable time.
Caution
If comfort mode "luxury" is selected in menu
2.2 no further increase can be carried out.
The function is activated immediately when a time period
is selected and confirmed using the OK button. The time
to the right displays the remaining time at the selected
setting.
When the time has run out F1145 returns to the mode
set in menu 2.2.
Select "off" to switch off
Menu 2.2 - comfort mode
Setting range: economy, normal, luxury
Default value: normal
The difference between the selectable modes is the
temperature of the hot tap water. Higher temperature
means that the hot water lasts longer.
42
Chapter 8 |
Control - Menus
2.1 - temporary lux
2.2 - comfort mode
2.3 - scheduling
2.9 - advanced
there are several sub-menus.
Activation of temporary increase in the
Setting hot water comfort. The status
temporary lux
.
Overview
2.9.1 - periodic increases
economy: This mode gives less hot water than the other,
but is more economical. This mode can be used in smaller
households with a small hot water requirement.
normal: Normal mode gives a larger amount of hot water
and is suitable for most households.
luxury: Lux mode gives the greatest possible amount of
hot water. In this mode the immersion heater may be
partially used to heat hot water, which may increase op-
erating costs.
Menu 2.3 - scheduling
What hot water comfort the heat pump is to work with
can be scheduled here for up to two different time peri-
ods per day.
Scheduling is activated/deactivated by ticking/unticking"ac-
tivated". Set times are not affected at deactivation.
If two settings conflict with each other a red exclamation
mark is displayed.
Schedule: The schedule to be changed is selected here.
Activated: Scheduling for the selected period is activated
here. Set times are not affected at deactivation.
Day: Select which day or days of the week the schedule
is to apply to here. To remove the scheduling for a partic-
ular day, the time for that day must be reset by setting
the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected
day for scheduling are selected here.
Adjusting: Set the hot water comfort that is to apply
during scheduling here.