Menu Level 2: Low Voltage Cut-Off - Waeco CoolAir SP950T Installation Manual

Hide thumbs Also See for CoolAir SP950T:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 34
Installation
7.3.3

Menu level 2: Low voltage cut-off

The battery monitor protects the battery from excessive discharging.
A
NOTICE!
When the battery monitor switches the device off, the battery only has
part of its charging capacity. Avoid starting repeatedly or operating elec-
trical consumers. Make sure that the battery is recharged. As soon as
the required voltage is available again, the unit can be operated again.
If only the set power supply is available here for the air conditioning roof
unit, the unit is switched off.
➤ Start configuration mode (chapter "Starting and ending configuration
mode" on page 48).
✓ The first digit of the display (fig. 0 5,page 8) shows the menu level
and the second and third show the parameter which can be set.
➤ Press the + button (fig. 0 6,page 8) once to switch to menu level 2.
➤ Press the Operating Mode button (fig. 0 4,page 8) to change the
parameter.
✓ The digits in the display flash until the parameter you entered is
confirmed.
➤ Use the + and – buttons (fig. 0 6 and 7, page 8) to set the value for
low voltage shutdown. The characteristic figures at second and third
place on the digital display represent the voltage (V) at which the unit
is shut down:
Characteristic
figure
➤ Press the Operating Mode button (fig. 0 4,page 8) to confirm your
entry.
✓ The set value is saved and is then used when the unit is restarted.
✓ You are now in menu level 2 again and can use the + and – buttons to
switch between menu levels.
50
Low voltage
shutdown
22.2
1
22.4
2
22.6
3
22.8
4
22.9
5
CoolAir RT880, SP950T
Characteristic
Low voltage
figure
shutdown
6
7
8
9
10
23.0
23.1
23.2
23.4
23.6
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Coolair rt880

Table of Contents