Furuno DRS2D Installation Manual page 24

Radar sensor
Hide thumbs Also See for DRS2D:
Table of Contents

Advertisement

5
3. Insert wires of cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside the
radar sensor, consulting the label on the connector for location. As for shield, use the cable
clamp shown below.
Cable
Clamp
Use the clamp pre-attached inside the radar
sensor.
15
Shield
370
Wind vinyl tape.
(supplied)
65
20
15 (Area fastened with the cable clamp)
Fabrication of CB-05BFFM cable
M12-05BFFM (φ6)
Cable clamp
CB-05BFFM cable
Fasten the cable tie (supplied) within
15 mm from the end of vinyl sheath.
CB-05BFFM cable
Use the clamp supplied with the optional gasket
(Type: OP03-203,
Zoom up
Location of the cable clamp
Attach the cable clamp
using this screw for CB-
05BFFM cable. (Face
projecting part down.)
17
CB-05BFFM (φ10)
Code No.: 001-025-290)