• a separate lighted green LED for each Fibre
Channel port shows activity and an unlit LED
means no activity.
Inspect the front side LEDs (iPBridge 2700R/D
only) (see Exhibit 6.0-2):
• a green power LED; on means power is on; off
means power is off.
• a yellow LED on each Ethernet port indicates
100/1000 Mb/sec. speed, where off means 100
Mb/sec. and on means 1000 Mb/sec.
• a green LED on each Ethernet port activity,
where off means no activity and on means
activity.
• a bicolor LED on each Fibre Channel port
indicates FC speed. Off is 1G FC, green is 2G
FC and yellow indicates 4G FC.
• a green LED on each Fibre Channel port
indicates activity, where off means no activity
and on means activity.
Check for problems on attached devices
Check the following in order to find problems on
attached devices:
• LEDs
• Display panels
• Firmware levels
• Operability
Exhibit 6.0-1 iPBridge 2700C faceplate
Fibre Channel ports
LEDs
Exhibit 6.0-2 iPBridge 2700 R/D front label
21
ATTO Technology Inc. iPBridge Installation and Operation Manual
FC Link FC Activity GbE Speed GbE Activity
Check host versions
Check the following to find problems on attached
hosts:
• Operating system version
• Service pack version
• Host adapter version
• Host adapter firmware version
• Host adapter device driver version
• iSCSI driver version
If an update is required, perform the update. For
an updated list of supported iPBridge host
platforms and host adapters, visit
.
www.attotech.com
Check iPBridge product versions and

update firmware

1
Enter ATTO ExpressNAV.
2
Check the version numbers on the Status
page.
3
For a current list of updates, visit
www.attotech.com.
If an update is needed, download the update
www.attotech.com
from
4
Go to the Firmware Update page in ATTO
ExpressNAV and follow the instructions in
Updating firmware
If the update does not work, use the FTP method
to download the firmware update and verify that
your FTP client is set for binary mode
GbE ports
Ethernet port
Link
.
on page 19.
10/100
Reset
button
Activity
Ready/Fault

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipbridge 2700dIpbridge 2700r

Table of Contents

Save Article as PDF