10
Item
Type
Image pickup device
CCD camera
Image recording
LCD monitor*
External interfaces
Power supply
Dimensions/weight
Operating environment
* Depending on the combination of the microscope and TV adapter in use, the directions of observation images may not
correspond each other in the eyepiece and on the LCD monitor. Should this be the case, switch the picture display orientation
to up/down inverted display (P. 25).
38

SPECIFICATIONS

C-mount CCD camera unit & control box
1/1.8-inch, 3.34 million pixels (3.24 million pixels effective).
RGB primary color on-chip filters.
Effective pixels: 2088(H) x 1550(V) pixels
Sensitivity: ISO 25/50/100 equivalent.
Photometry methods: Center-weighted average method (30% in center), spot metering
Exposure control: AUTO, MANUAL, AE LOCK.
Exposure time: AUTO (1/2 to 1/4000 sec. [exposure compensation ±2 EV])
White balance control: Full auto, once-touch, manual (color temperature selection from
Image recording medium: 3.3 V SmartMedia (SSFDC) with 32 MB capacity.
Recording formats: Digital recording, JPEG, DCF (Design rule for Camera File system),
Recording pixels: 2048 x 1536 pixels in SHQ/HQ modes, 1024 x 768 or 640 x 480 pixels
3.5-inch TFT color LCD (approx. 200,000 pixels).
PC connection: USB connector (type B).
Video output: RCA pin jack.
Supply voltage: 6 V DC ±10%.
Supply current: 2.5 A.
Camera unit: 119(W) x 110(D) x 53(H) mm, approx. 440 grams.
Control box: 131(W) x 165(D) x 177(H) mm, approx. 690 grams.
· Indoor use.
· Altitude: Max. 2000 m
· Ambient temperature: 5° to 40°C (41° to 104°F)
· Maximum relative humidity: 80% for temperatures up to 31°C (88°F), decreasing lin-
early through 70% at 34°C (93°F), 60% at 37°C (99°F), to 50% relative humidity at 40°C
(104°F).
· Supply voltage fluctuations; Not to exceed ±10% of the normal voltage.
· Pollution degree: 2 (in accordance with IEC60664)
· Installation/Overvoltage category: II (in accordance with IEC60664)
Specification
method (1% in center).
MANUAL (8 to 1/4000 sec.)
3000K, 3700K, 4000K, 4500K, 5500K and 6500K).
(2, 4, 8, 16, 64 and 128 MB cards can also be used.).
TIFF (non-compressed). DPOF compatible.
in SQ mode.

Advertisement