Sv & P Smart Probe Profile Input; Operational Procedures - Kongsberg EM 1002 Operator's Manual

Hydrography multibeam echo sounder
Hide thumbs Also See for EM 1002:
Table of Contents

Advertisement

Note:
5.5

Operational Procedures

850--160977/E
SV & P Smart Probe Profile Input
When SV & P Smart Probe Profiling is enabled under Profiling
Input, the SV & P Smart Probe Profile Input controls at the
bottom of the I/O Interfaces dialogue box become active for
selection.
Figure 59 - The Device controls dialogue box, SV & P Smart Probe
Push to start Logging Probe Data
This button is used to start the collection of probe data in order to
established a complete sound speed profile. The sampling process
runs until you press the button again.
Please note that the probe starts sampling data as soon as it is
enabeled in the main window!
Probe depth
This field displays the current probe depth as a function of the
pressure read by the sensor. The information is continuously
updated once the sensor is activated.
Sound speed
This field displays the current sound speed as read by the sensor.
The information is continuously updated once the sensor is
activated.
The following procedure allows you to collect the sound speed
profile using the Applied Microsystem's Smart SV&P Probe
connected to the EM 1002 Operator Station. The procedure
assumes that you have defined a serial line input for the probe.
Profiling
I/O Interfaces
155