INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along
with your primary heating system. Do not install this heater as your primary heat source.
If you have a central heating system, you may run system's circulating blower while
using heater. This will help circulate the heat throughout the house.
CAUTION: If you install the heater in a home garage:
• Heater pilot and burner must be at least 18 inches above the floor.
• Place heater where moving vehicle will not hit it.
WARNING: A qualified technician must install heater. Follow all local codes.
WARNING: Never install the heater:
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less
than 36 inches from the front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates warm air currents. These currents move heat to wall
surfaces next to heater. Walls may become discolored if you install or operate your heater
or use impurities, such as tobacco smoke, aromatic candles, cleaning fluids, oil, or kerosene
lamps, etc., next to vinyl or cloth wall coverings.
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from
floor, ceiling and adjoining side and back walls.
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial,
installing heater in rooms without enough ventilation air may cause mildew to form from too
much moisture. See Air for Combustion and Ventilation, pages 7 through 9.
CHECK GAS TYPE
Be sure your gas supply is right for your heater.
Otherwise, call dealer where you bought the
heater for proper type heater.
CLEARANCES TO COMBUSTIBLES
Carefully follow the instructions below.
This heater is a wall mount unit designed
to sit directly on the floor or on a mantel base.
WARNING: Maintain the minimum
clearances shown in Fig. 3. If you
can, provide greater clearances
from floor, ceiling, and joining wall.
Fig. 3 - Mounting clearances as
viewed from front of heater (inches)
Minimum
Side of
Heater
LEFT SIDE
FLOOR
10
CEILING
6 in.
From
36 in.
Control Knob
Minimum
RIGHT SIDE
2 in. Minimum to Surface of Carpeting.
Tile, or Other Combustible Material