Always remove the battery before starting any troubleshooting or repairs on the machine.
Fault
Machine switches off during operation
Running time is too short
Battery gets stuck during insertion in the
machine/charger
Battery does not charge although the LEDs
on the charger are green
LED on charger flashes red
40
Cause
Battery or machine electronics too hot
Electrical malfunction
Battery is not completely charged
Service life of battery has been reached
or exceeded
Guides dirty
Battery too hot / too cold
(1 LED on battery is red)
No electrical contact between charger
and battery
Fault in battery
(4 LEDs on battery flash red for
approx. 5 seconds)
Fault in charger
Remedy
Remove battery from the machine, let
battery and machine cool off
Remove battery and reinsert it
Charge battery
The battery will need to be tested by a
STIHL servicing dealer
Carefully clean guides
Let the battery cool down / let the battery
warm up at temperatures of 15 °C -
20 °C (59 °F - 68 °F)
Operate the charger only in a dry space
at ambient temperatures of +5 °C to
+40 °C (41 °F - 104 °F)
Remove battery and reinsert it
Remove the battery from the machine
and reinsert it. Switch on the machine –
if the LEDs still flash, the battery is faulty
and must be replaced
Have charger tested by a STIHL servic-
ing dealer