2.2.6 Serial port configuration commands

The ATTO iPBridge serial ports or serial headers are configured with default settings but may be
customized to your specifications using the CLI commands in this section.

SerialPortBaudRate

Configures/reports the baud rate for the iPBridge RS-232
serial port or serial header. The number of data bits per
character is fixed at 8 with no parity. Choices are 2400,
9600, 19200, 38400, 57600 and 115200.
Default: 115200
Set syntax: set SerialPortBaudRate [2400 | 9600 |19200
| 38400 | 57600 |115200]
Requires a SaveConfiguration command
Get syntax: get SerialPortBaudRate
33
ATTO Technology Inc. iPBridge Installation and Operation Manual

SerialPortEcho

Enables/disables/reports the echoing of keyboard input.
When enabled, all non-control character keyboard input
is output to the display.Local ASCII terminal (or terminal
emulator) echo settings should be set to disabled while
using SerialPortEcho enabled
Default: enabled
Set syntax: set SerialPortEcho [enabled | disabled]
Requires a SaveConfiguration Restart command
Get syntax: get SerialPortEcho