Component Removal

Drawer Assembly and Choke Cover Removal:

1. Follow the Drawer Microwave disassembly as previ-
ously stated on page 4-6.
2. Open the drawer and keep it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Remove the both right and left side cabinet panels.
5. Remove the two drawer support covers from the
choke cover as shown in Figure 4-10.
6. Insert a putty knife or flat thin blade screwdriver
(thickness of about 0.5mm) into the gap between the
choke cover and the door frame (See Figure 4-10).
7. Carefully slide choke cover away from drawer as far
as possible.
8. Extract six mounting screws from all three drawer
support angles as shown in Figure 4-11.
9. Unhook the drawer support angles from the drawer,
then remove.
10. Now, the door assembly is free and the choke cover
can now be removed.

Drawer Support Angle Removal:

1. Remove the drawer assembly and choke cover first.
2. Remove two mounting screws from the right or left
latch angle assembly, then remove angle assembly
(See Figure 4-12).
3. Separate slide rails by moving inside lever of slide
rail. The slide rail will now separate by pulling
straight forward and out (See Figure 4-13).
4. At this point, you can replace either latch angle assy
or latch angles.
To reassemble, just reverse the above order.
#813632 - Revision B - December, 2009
Drawer Microwave
4-10
(Models MWD24-2 / MWD30-2)
s
g l e
A n
o r t
p p
S u
e r
a w
D r
Figure 4-10. Choke Cover Removal
D r a w
Screws
Bottom Drawer
Support Angle
Bottom of unit
Figure 4-11. Drawer Support Screw Removal
Latch Angle
Assembly
Screws
Figure 4-12. Latch Angle Assembly Removal
Lever
Figure 4-13. Disconnect Center Slides
Choke
Cover
e r S
u p p o
r t A n
g l e
Screws