Rack Gear Removal; Major Control Components - Wolf MWD24-2 Service Manual

Drawer microwave
Hide thumbs Also See for MWD24-2:
Table of Contents

Advertisement

Drawer Microwave

Rack Gear Removal:

1. Follow the Drawer Microwave disassembly as previ-
ously stated on page 4-6.
2. Open the drawer and keep it open.
3. To discharge the high voltage capacitor, wait for 60
seconds.
4. Remove the drawer microwave by following steps 1,
2, 5, 8, 9 & 10 as instructed under "Drawer Assembly
and Choke Removal".
5. Remove the three (3) mounting screws holding the
rack gear to the bottom slide rail (See Figure 4-17).
7. Proceed in reverse to reinstall the new rack gear.

Major Control Components:

1. Drawer Microwave must be removed from its installation. Remove the top plate, both side cabinet panels, the
exhaust duct and the back plate.
2. Only attempt to remove a major control component after allowing the capacitor to self discharge which takes
approximately 60 seconds, or discharge capacitor as instructed on page 4-3.
3. All major control components are attached with phillips head screws. To Remove a component, extract its
mounting screws after detaching electrical wiring.
NOTE: Be careful to maintain proper wire location. Check for clear wire marking before removing any wires and
label any wires that can not be easily identified.
HV
Capacitor
(Models MWD24-2 / MWD30-2)
Thermal
Cut-Out
Magnetron
HV Trans-
former
Drawer Microwave Major Control Components
Bottom
Drawer
Support
Bottom
view of unit
Figure 4-17. Rack Gear Removal
Fan Motor
Power
Supply
4-13
Component Access
Rack
Gear
#813632 - Revision B - December, 2009
Screws
(Third screw
not shown)
Monitor
Fuse

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mwd30-2

Table of Contents