Troubleshooting Guide
PROCEDURE LETTER
E
#813632 - Revision B - December, 2009
Drawer Microwave
PROCEDURES TO BE TAKEN WHEN THE FUSE ON THE PRINTED WIRING
BOARD (PWB) IS OPEN:
To protect the electronic circuits, this model is provided with a fuse added to the
primary on the PWB.
1. Fuse check and repairs.
Disconnect the power supply cord.
Remove the outer case cabinet.
Open the door and block it open.
Discharge high voltage capacitor.
If the Fuse is blown, replace power unit.
Make a visual inspection of the varistor. Check for burned damage. If the
varistor has been burned, replace the power unit.
Examine the touch control transformer with a tester for the presence of
layer short-circuit (check the primary coil resistance which is approximate-
ly 151.6? ± 10%). If any abnormal condition is detected, replace the
touch control transformer.
Reconnect all leads removed from components during testing.
Re-install the outer case (cabinet).
Reconnect the power supply cord after the outer case is installed.
Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if indicator does not light up
after above check and repairs are finished.
Disconnect the power supply cord.
Remove the outer case cabinet.
Open the door and block it open.
Discharge high voltage capacitor.
Disconnect the leads to the primary of the power transformer.
Ensure that these leads remain isolated from other components and oven
chassis by using insulation tape.
After that procedure, re-connect the power supply cord.
Follow the troubleshooting guide given below for repair.
STEPS
OCCURRENCE
The rated AC voltage is not present
1
between Pin Nos. 5 and 7 of the 4-
pin connector (CN-A).
The rated AC voltage is present at
2
primary side of touch control trans-
Disconnect the power supply cord, and then remove outer case.
Open the door and block it open.
Discharge high voltage capacitor.
Reconnect all leads removed from components during testing.
Re-install the outer case (cabinet).
Reconnect the power supply cord after the outer case is installed.
Run the oven and check all functions.
5-8
(Models MWD24-2 / MWD30-2)
COMPONENT TEST
ondary circuit defective.Check and
replace touch control transformer or
former.
CAUSE OR CORRECTION
Check supply voltage and oven
power cord.
Touch control transformer or sec-
power unit.