Upper Cabinet Component Replacement; Cavity Light Replacement; Power Cord Replacement - Wolf MWD24-2 Service Manual

Drawer microwave
Hide thumbs Also See for MWD24-2:
Table of Contents

Advertisement

Drawer Microwave
Upper Cabinet Component Replacement: (Sensor,
Stirrer Motor, Upper Thermal Limiter)
1. Drawer Microwave must be removed from its instal-
lation. See Drawer Microwave Disassembly (page 4-
6) steps 1-3.
2. Wait 60 Sec. to discharge High Voltage Capacitor.
3. Using a phillips screwdriver, remove the two mount-
ing screws (one on each side of the stirrer motor)
that fasten the stirrer motor assembly to the top of
the unit (See Figure 4-5).
NOTES:
• The stirrer motor shaft has flat spots that must be
aligned with the stirrer fan assembly for reinstalla-
tion.
• Please see "After Servicing" (Page 4-11) when
repair is complete.

Cavity Light Replacement:

1. Drawer Microwave must be removed from its instal-
lation. See Drawer Microwave Disassembly (page 4-
6) steps 1-3.
2. Locate and remove lamp access panel in top plate
(See Figure 4-3 on page 4-6).
NOTE: Lamp and socket are an assembly. You
must change socket along with the lamp.
3. Remove lamp socket screw to remove the lamp
assembly and replace with new (See Figure 4-6).

Power Cord Replacement:

1. Un-hook the black and white AC terminals from the
noise filter PWB and green ground wire from the
back plate (See Figure 4-7).
2. Attach the black and white AC terminals from the
new power cord to the noise filter as shown in figure
4-7.
NOTE: The green ground wire terminal can be attached
when reassembling the back plate to the drawer cavity.
(Models MWD24-2 / MWD30-2)
Screw
Stirrer
Motor
Figure 4-5. Upper Components
Figure 4-6. Lamp & Socket Removal
Green
Ground Wire
Black Plate
Figure 4-7. Power Cord Replacement
4-7
Component Access
Screw
Power
Cord
Black
Wire
#813632 - Revision B - December, 2009
White
Wire

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mwd30-2

Table of Contents