MINIMUM ALCOVE CLEARANCE AND CLEARANCE TO COMBUSTIBLE MATERIALS
MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84"
Maximum depth of alcove - 36"
Unit
From Back Shield
G
CS2400
15"

Floor Protection

A combustible floor must be protected by a non-combustible material (like tile,
concrete board, or certified to UL-1618 or as defined by local codes) extending
beneath the heater and a minimum of 6" from each side and minimum 16" from
the fuel door opening of the stove and minimum 6" (or the rear clearance to
combustibles whichever is smaller) from the rear of the stove.
NOTE: In Canada, floor protection must extend 18" to the front and 8" to
each side of the stove.
Minimum Overall Width (X) of Floor
Protector for all installations:
US
38-3/8"
Canada
42-3/8"
Note:
If venting horizontally, floor protection must extend under the chimney connector and 2" inches beyond each side.
Unit
CS2400
USA
Canada
8
|
Regency CS2400 Freestanding Wood Stove
FROM THE REAR HEAT SHIELD TO A BACK WALL
Minimum Alcove Clearance to Combustible Materials
+ Side Shields.
H
6.5"
Minimum Overall Depth (Y) of Floor Protector
Residential
"C" Vent
Y
Z
47-5/16"
6"
51-5/16"
8"
From Flue
Center-Line
I
J
28"
14-7/8"
6"
6"
6"
for angled corners
Residential
Mobile Home
Close Clearance
Close Clearance
Z
Y
Y
47-5/16"
6"
47-5/16"
51-5/16"
8"
51-5/16"
I
Min.
Min. Hearth
Width
to Rear Wall
K
L
56"
47-1/2"
Z
6"
X
I
Y
16"
16"
X
6"
Y
Alcove
Z
Y
6"
47-5/16"
8"
51-5/16"
Fuel Door
Opening
6"
Z
Z
6"
8"