Regency Alterra CS1200 Owners & Installation Manual

Freestanding wood stove

Advertisement

Quick Links

CS1200
®
Alterra
Freestanding
Wood Stove
Owner's & Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-896a
11/08/10

Advertisement

Table of Contents
loading

Summary of Contents for Regency Alterra CS1200

  • Page 1 CS1200 ® Alterra Freestanding Wood Stove Owner's & Installation Manual Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-896a 11/08/10...
  • Page 2 The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
  • Page 3: Safety Label

    CS1200 Wood Stove. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 4: Table Of Contents

    Lower Surround reversal ..........18 Door reversal ...............19 Wood Storage ..............20 Ashlip Installation............20 Blower/Fan installation ..........21 Fan Operation..............21 Fan wiring ..............21 OPERATING INSTRUCTIONS Operating Instructions ..........22 First Fire ..............22 Draft Control ..............22 Ash Disposal..............23 Safety Guidelines And Warnings .........24 Regency CS1200 Freestanding Wood Stove...
  • Page 5: Dimensions

    DIMENSIONS UNIT DIMENSIONS Shown with optional 27-1/8” (689mm) blower installed. 6" fl ue collar 17-1/8” (436mm) 19-1/16” (485mm) 17-1/8” (436mm) 26-3/4”(680mm) Regency CS1200 Freestanding Wood Stove...
  • Page 6: Installation

    Be aware that local Codes and Regulations may fl oor protector. override some items in this manual. Check with 13) Your Regency Wood stove is not to be connected your local inspector. to any air distribution duct. 7) The fl oor protector must be of non-combustible material and must extend 16"...
  • Page 7: Minimum Clearance To Combustible Materials

    Mobile Home Close Clearance (To be installed with required pipe components) "C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.) From Unit From Corner From Flue Center-line CS1200 11" 7" 7" 24-1/2" 14.5" 19-3/4" Regency CS1200 Freestanding Wood Stove...
  • Page 8 MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND FROM THE REAR HEAT SHIELD TO A BACK WALL The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level.
  • Page 9: Step By Step Chimney And Connector Installation

    6) Fasten the raincap with spark screens (if re- quired) to the top of your chimney. 7) For optimum effi ciency when installing into a masonry chimney, size accordingly, i.e. the 6" (152mm) fl ue dia. is 28.28 sq.in. Horizontal Installation Regency CS1200 Freestanding Wood Stove...
  • Page 10: Masonry Chimney

    The chimney must be the required height above the roof or other obstructions for safety and proper draft operation. The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629, Standard for 650 C Factory-Built Chimneys. Regency CS1200 Freestanding Wood Stove...
  • Page 11: Combustible Wall Chimney Connector Pass-Throughs

    24 gage minimum sheet metal supports. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure chimney fl ue liner. Regency CS1200 Freestanding Wood Stove...
  • Page 12: Recommended Heights For Woodstove Flue

    = 4 ft. one "T" = 3 ft. Total Addition (at sea level) = 9 ft. Recommended Flue Height Elevation Example a) Example b) 1000' 18.72' 21.84' 2000' 19.44' 22.68' 5000' 21.60' 25.20' 8000' 23.76' 27.72' Regency CS1200 Freestanding Wood Stove...
  • Page 13: Mobile Home Installation

    WARNING: Operate only with door fully closed - open feed door to feed fi re only. 4" outside air kit Secured to fl oor with 2 lag bolts. Regency CS1200 Freestanding Wood Stove...
  • Page 14: Listed Components For Mobile Home Installation

    INSTALLATION LISTED COMPONENTS FOR MOBILE HOME INSTALLATION The Regency CS1200 is approved for installation in a Mobile Home if one of the following pipe systems is used. U.S. Installation* Qty.Part # Description METALBESTOS SSII 6DCC Connector Qty. Part # Description...
  • Page 15: Baffl E And Tube Installation

    4) Important: push both baffl e bricks so they are tight against the side walls. Note: When getting the chimney cleaned, remove the baffl e bricks for access to the fl ue, then replace them when cleaning is completed. Handle stored on hangar in wood storage area. Regency CS1200 Freestanding Wood Stove...
  • Page 16: Side Panel Installation

    Failure to do this will result in burn stains on panels which you will be unable to remove. Not protected by product warranty. 4) Install Regency logo on to the 1) Bend the metal tab (located in the top front corner of the side panels to left side panel - by snapping a 45°...
  • Page 17: Ash Drawer Option

    - it is directly below the upper ash dump plate.) by removing the two nuts and bolts holding the 2 plates together from underneath the stove. Ash Dump Plates Ash Plug Keep ash removal tool handy for maintenance - see ash disposal in operating instructions. Regency CS1200 Freestanding Wood Stove...
  • Page 18: Lower Surround Reversal

    5) Remove and rotate both the male part of the latch 180° - located on the inside of the lower surround door. Install the latch on the opposite side of the door. Door latch - male portion Regency CS1200 Freestanding Wood Stove...
  • Page 19: Door Reversal

    4) Flip the door hinge 180° - install on the left side of the unit with 2 bolts. 5) Reattach the door catch assembly on the right side with 2 bolts from step Door 9) Reattach the door to the door hinge. Hinge Door Catch Regency CS1200 Freestanding Wood Stove...
  • Page 20: Wood Storage

    Tabs on ashlip Store wood behind door opening OPTIONAL ASHLIP INSTALLATION 1) Open lower surround door. Final install of Ashlip 2) Ashlip to be positioned just below the ashdrawer (if installed). Ashlip to be positioned here Regency CS1200 Freestanding Wood Stove...
  • Page 21: Blower/Fan Installation

    CAUTION: Label all wires prior to disconnection hazard and should be plugged directly into a properly when servicing controls. Wiring errors can cause grounded three-prong receptacle. Do not cut or remove improper and dangerous operation. the grounding prong from this plug. Regency CS1200 Freestanding Wood Stove...
  • Page 22: Operating Instructions

    fl ue to establish the fi re. (Leaving Regency Stove causing a draft down your the door slightly open will help your fi re start chimney. If this occurs, slightly open a window more rapidly.)
  • Page 23: Ash Disposal

    2) Always leave 1/2 to 1 inch of ash in the bottom of the fi rebox. This helps in easier starting and a more uniform burn of your fi re. Replace ash plug when ashes have been removed. Regency CS1200 Freestanding Wood Stove...
  • Page 24: Safety Guidelines And Warnings

    Failure to do so can result in a serious chimney fi re. 7) Your Regency stove can be very hot. You may be seriously burned if you touch the stove while it is operating, keep children, clothing and furniture away.
  • Page 25: Maintenance

    If the door gasket requires replacement 7/8" diameter fresh wood. This allows the wood to achieve material must be used. Regency uses AMATEX # 10- the charcoal stage faster and burns up any 863KR 7/8" dia. gasket. A proper high temperature unburned gas vapours which might otherwise gasket adhesive is required.
  • Page 26: Parts List

    Door Hinge Assembly 942-110 Ash drawer plug * Not available as a replacement part 076-911 Ash Drawer Assembly 076-004 Fan Opening Cover 076-010 Back Shield 074-954 Air tube 033-953 Air tube 073-955 Baffl e set 076-913 Ashlip Regency CS1200 Freestanding Wood Stove...
  • Page 27: Fan Assembly

    Fan Housing Front 222-022 Fan Housing Bottom 222-036 Sensor Mount 200-227 Fan Bracket Right Hand 200-228 Fan Bracket Left Hand 200-229 Fan Housing Back 910-157/P Fan 910-142 Thermodisc FIRE BRICK Part # Description 076-960 Firebrick Set Regency CS1200 Freestanding Wood Stove...
  • Page 28 NOTES Regency CS1200 Freestanding Wood Stove...
  • Page 29 NOTES Regency CS1200 Freestanding Wood Stove...
  • Page 30 NOTES Regency CS1200 Freestanding Wood Stove...
  • Page 31: Warranty

    The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 32 ® Register your Regency warranty online www.regency-fi re.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notifi cation of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Cs1200

Table of Contents