Page 1
Owners & Installation FREESTANDING WOOD FIRE Models: F2452 (Windsor/Hamilton) MODEL: Hamilton MODEL: Windsor PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult an authorised installer, service agency or the distributor.
Page 2
CO such as heater fueling areas. "This manual describes the installation and operation of the Regency F2452 wood heater. This heater generates the best efficiency when operated using well-seasoned wood and installed in the main living areas where the majority of the chimney is within the building envelope. "This wood heater needs periodic inspection and repair for proper operation.
Copy of Data Badge ............4 Operation Dimensions Operating Instructions ..........19 Draft Control ..............19 Unit Dimensions ..............5 First Fire ..............20 Arched Door ..............5 Fan Operation ..............21 Square Door ..............5 Ash Disposal ..............21 Outside Air Dimensions ............. 5 Ash Drawer Operating Guidelines .......21 Safety Guidelines and Warnings .........21 Installation...
This is a copy of the label that accompanies NOTE: Regency units are constantly being each Regency Freestanding Wood Fire (F2452). improved. Check the data badge on the unit We have printed a copy of the contents here and if there is a difference, the data badge on for your review.
Modular Installation Options WARNING: ONLY USE SPECIFIED COMPONENTS. The following items are required when assembling your Regency Stove. The Rear Heat Deflector is supplied with the stove, but if you choose not to use it you must use the Airmate instead...
Loosen the screws on the rear on the stove (3 per Diagram 1 side), slide the side panel up as far as possible and then secure by tightening the screws. Screws Diagram 2 Diagram 3 Diagram 5 F2452 Regency Freestanding Wood Fire...
Fibre washer Shown with Classic door Logo Installation 1. Push the Regency logo into 6. Reinstall cover plate if not using ash drawer option. the two holes in the front bottom left corner of 7. Install logo plate onto heat shield by placing in 2 holes as the pedestal cover shown in diagram.
(Refer to Diagram 1) Door hinges Wood handle Door Door handle Hinge Cap Cover Diagram 2 tooltip Diagram 3 F2452 Regency Freestanding Wood Fire 919-967a 04.03.19...
After use, store the door handle on the storage hook located on the left side of the appliance. Tool Holder Handle WARNING: FAILURE TO USE REMOVABLE HANDLE AS PER INSTRUCTIONS MAY CAUSE SERIOUS BURNS. 919-402a 03/10/21 F2452 Regency Freestanding Wood Fire...
3000 3000 3000 THE FLUE PIPE SHALL EXTEND NOT LESS THAN 4.6 M ABOVE THE TOP OF THE FLOOR PROTECTOR. NOTE: INSTALLATION MUST BE CARRIED OUT BY A LICENSED INSTALLER IN ACCORDANCE WITH AS/NZS 2918:2018 F2452 Regency Freestanding Wood Fire...
NOTE: The "AD" brick in the drawings above is the brick covering the Ash Dump hole that is used when the Ash Drawer Kit is installed (refer to the Listed Components for Mobile Home Installation section). F2452 Regency Freestanding Wood Fire...
4 . Install the 2 front secondary air tubes with pliers and hammer to lock them 2. Slide the left baffle over the 2 remaining air tubes from the front and then into place, as shown below. push it to the back. Side View 5. Reverse Step 1. F2452 Regency Freestanding Wood Fire...
Wiring errors can cause improper and dangerous operation. Neutral Green Manual/ Live Ground Auto 240V AC 120V AC Switch Switch 60 Hz 50Hz Fan Thermodisc (normally open) Black Black Black Ground Wiring Diagram 908-126a 04/08/14 F2452 Regency Freestanding Wood Fire...
WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Ensure deflector is seated so bolts are situated at the top of the keyhole before tightening. F2452 Regency Freestanding Wood Fire...
Left - Open Right - Closed WARNING: To build a fire in igno- rance or to disregard the information contained in this section can cause serious permanent damage to the unit and void your warranty. F2452 Regency Freestanding Wood Fire...
If you also have a fireplace in your home, a downdraft may be created by your WARNING: Never build a roaring fire in Regency Stove causing a draft down your a cold stove. Always warm your stove chimney. If this occurs, slightly open a window near your unit.
3. Never start a fire if the ash plug and ash drawer are not in place. This will cause over firing which 8. Your Regency stove can be very hot. You may be can cause excessive warping of the stove.
DUCT WORK UNLESS SPECIFICALLY AP- PROVED FOR SUCH INSTALLATION. Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you Glass Replacement (Square Door) break your glass by impact, purchase your replacement from an authorized Regency dealer only.
Door Gasket If the door gasket requires replacement 19mm diameter material must be used. Regency uses a 19mm gasket rope (Part #846-570). A proper high temperature gasket adhesive is required. See your Regency Dealer.
We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized brush and special vacuum cleaner designed to deal with fine particles. F2452 Regency Freestanding Wood Fire...
2. Loosen the two 11mm' bolts + nuts to remove / replace vertical deflector. 3. Repeat steps to install new vertical deflector. NOTE: ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE. TIGHT TO TOP OF FIREBOX. F2452 Regency Freestanding Wood Fire...
Small Square Black Door Complete 156-241 Cast Handle 846-975 Door Handle Assembly (does not include cast handle) 846-570 Door Gasket Repair Kit 829-489 Cast Handle Holder 948-082 Black Door Hinge Caps (each) N/S = Not Shown F2452 Regency Freestanding Wood Fire...
Brick - Regular Full Size: 32mm x 114mm x 229mm Brick Partial: 32mm x 51mm x 114mm Brick Partial: 32mm x 114mm x 89mm Brick Partial: 32mm x 51mm x 229mm NOTE: This kit contains one spare brick in case of breakage. F2452 Regency Freestanding Wood Fire...
FPI Fireplace Products International Ltd. (“the manufacturer”) through its wholly owned subsidiary, Fireplace Products Australia Pty Ltd (for Australia and New Zealand customers) and sold under the Regency® brand of fireplace products (collectively referred to herein as “FPI”), extends this Limited Warranty to the original purchaser of this appliance provided the product remains in the original place of installation.
Page 32
Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorisation from FPI may void this warranty. INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY. A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Revision Date: December 2016 Regency Wood Products Warranty F2452 Regency Freestanding Wood Fire...
Page 33
(b) Loss means any expense, cost or damage of any kind and includes Consequential Loss and a fine or penalty imposed by a statutory or other authority. Revision Date: December 2016 Regency Wood Products Warranty F2452 Regency Freestanding Wood Fire...
Page 34
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx...
Page 35
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.