Mitsubishi SRK18CL Technical Manual & Parts List page 6

Table of Contents

Advertisement

Item
Cooling capacity (1)
Power supply
Power
consumption
Running
current
Operation
data (1)
Inrush current
COP
Noise
Cooling
level
Exterior dimensions (Height x Width x Depth)
Exterior appearance
(Munsell color)
Net weight
Compressor type & Q'ty
Motor (Starting method)
Refrigerant oil
Refrigerant
Refrigerant (3)
equipment
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Air handling
Air flow
equipment
Fresh air intake
Air filter, Quality / Quantity
Shock & vibration absorber
Operation switch
Operation
Room temperature control
control
Operation Display
Safety devices
Refrigerant piping size (O.D)
connecting method
Attached length of piping
Installation
data
Insulation for piping
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Drain hose
Power cable
Recommended breaker size
Connection wiring
Accessories (included)
Optional parts
Note (1) The data are measured at the following conditions.
Item
Operation
Cooling
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even for the short piping.)
Model
W
Cooling
kW
Cooling
A
Cooling
Sound level
dB(A)
Power level
dB
mm
kg
kW
kg
W
Cooling
CMM
mm
m
m
A
Size x Core number
Connecting method
Indoor air temperature
DB
WB
27˚C
19˚C
Indoor unit SRK18CL-6
1 Phase, 220/230/240V, 50Hz
8.1/7.8/7.4 (220/230/240V)
Hi : 48 Me : 44 Lo : 42
64
309 x 890 x 251
Fine snow
(8.0Y 9.3/0.1) near equivalent
12
0.45 (SONISO 4GSI or ATMOS NM56)
R22 0.9 (Pre-Charged up to the piping length of 7m)
Louver fins & inner grooved tubing
Microcomputer control
Tangential fan x 1
27
12.8
Not possible
Polypropylene net (washable) x 2
Wireless-Remote control
Microcomputer thermostat
RUN : Green, TIMER : Yellow, HI POWER : Green,
Compressor overheat protection, Overcurrent protection,
Frost protection, Fan motor error protection
Liquid line: φ6.35 (1/4") Gas line: φ15.88 (5/8")
Liquid line : 0.55
Gas line : 0.49
Necessary (Both sides), independent
Max.10 (Outdoor unit is higher)
Max.10 (Outdoor unit is lower)
Connectable (VP 16)
2
1.5mm
x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Outdoor air temperature
DB
WB
35˚C
24˚C
ISO-T1, JIS C 9612

-
-
'12 • SRK-T-125
SRK18CL-6
Outdoor unit SRC18CL-6
5000
1.72
37
2.91
50
65
640 x 850 (+65) x 290
Stucco white
(4.2Y 7.5/1.1) near equivalent
37
QJ292PBB(Rotary type) x 1
1.29 (PSC starting)
M fins & inner grooved tubing
Capillary tubes
Propeller fan x 1
40
38
Cushion rubber (for compressor)
ECONO : Orange
Flare connecting
Max. 15
20
Mounting kit
The pipe length is 7.5m.
Standards

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk18cl-3Srk18cl-6

Table of Contents