■ What is auto restart function?

(2) Unit ON/OFF button

(a) Operation
(b) Details of operation
Function
Indoor temperature
operation mode
Cooling
Thermal dry

(3) Auto restart function

(a)
(b)
1)
2)
(J170)

(4) Custom cord switching procedure

(a) Modifying the indoor printed circuit board
(b) Modifying the wireless remote controller
1)
2)
Auto restart function
Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a power cut, and then automati-
cally resumes operations after the power has been restored.
The following settings will be cancelled:
1 Timer settings
2 HIGH POWER operations
NOTE
Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult with your dealer if this function needs to be
switched off.
When power failure occurs, the timer setting is cancelled. Once power is resumed, set the timer again.
Temporary run operation
The unit ON/OFF button on the unit operates ON/OFF temporarily when the remote control is not used.
Operation program
OPERATION MODE
:
Fan speed Flap/Louver Timer Switch
FAN SPEED
:
setting
AIR FLOW
:
Operation starts by pressing the unit ON/OFF button; it stops if
you press the button again.
NOTE
Do not hold the Unit ON/OFF button down for more than 5 seconds.
(Holding it down longer than 5 seconds sets the automatic cooling used during servicing or when relocating the air-conditioner.)
AUTO
AUTO
AUTO
– 15 –
Jumper wire (J170)
Jumper wire (J171)
(J171)

-
-
'09•SRK-DB-087D
'12 • SRK-T-125
Unit ON/OFF button
Cut