Mitsubishi SRK18CL Technical Manual & Parts List page 18

Table of Contents

Advertisement

Preparation of indoor unit
① Mounting of connecting wires
ⓐ Open the air inlet panel.
ⓑ Remove the lid.
ⓒ Remove the wiring clamp.
ⓓ Connect the connecting wire securely to the terminal block.
Use cable for interconnection wiring to avoid loosening of the
wires.
CENELEC code for cables Required field cables.
H05RNR4G1.5 (Example) or 245IEC57
H
Harmonized cable type
05
300/500 volts
R
Natural-and/or synth. rubber wire insulation
N
Polychloroprene rubber conductors insulation
R
Standed core
4or5 Number of conductors
G
One conductor of the cables is the earth conductor (yel-
low/green)
1.5 Section of copper wire (mm
Connect the connection wire securely to the terminal block. If
the wire is not affixed completely, contact will be poor, and it
is dangerous as the terminal block may heat up and catch fire.
Take care not to confuse the terminal numbers for indoor
and outdoor connections.
Earth lead wire shall be longer than the other lead wires for
the electrical safety in case of the slipping out of the cord
from the anchorage.
The earth line of power cord must be properly earthed.
Affix the connection wire using the wiring clamp.
ⓔ Fix the connecting wire by wiring clamp.
ⓕ Attach the lid.
ⓖ Close the air inlet panel.
In case of faulty wiring connection, the indoor unit stops, and
then the run lamp turns on and the timer lamp blinks.
② Shaping the pipe
Pipe
Drain hose
• Hold the bottom of the pipe and change its
direction before stretching it and shaping it.
④ Cautions when piping from the left and the rear center of the unit
[ Top View ]
L
e
t f
S
d i
e
P
p i
n i
g
Left rear piping
Left side piping
[Drain hose changing procedures]
1. Remove the drain hose.
2. Remove the drain cap.
• Remove the screw and
pull the drain hose,
while twisting.
2
)
CAUTION
③ Taping of the exterior
• Tape only the portion that runs through the wall.
Always tape the crossover wires with the pipe.
R
g i
t h
Right rear piping
3. Insert the drain cap.
• Remove it with hand
• Insert the drain cap which was removed
or pliers.
at procedure "2" securely using a hex-
agonal wrench etc.
Note: Be careful that If it is not inserted
securely, water leakage may occur.
-
The screw of the service panel is tightened securely.
Service panel
Piping is possible in the rear, left,
left rear, left downward, right or
downward direction.
S
d i
e
P
p i
n i
g
Right
Rear
Downward Left rear
Right side piping
4. Connect the drain hose.
• Insert the drain hose se-

-
'12 • SRK-T-125
Terminal block
Clamp
Left
Left downward
curely, Push the drain hose
while twisting. Install the
screw.
Note: Be careful that If it is
not Inserted securely, water
leakage may occur.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk18cl-3Srk18cl-6

Table of Contents