BEFORE INSTALLATION

Before installation check that the power supply matches the air conditioner.
Standard accessories
(Installation kit)
Accessories for indoor unit
Installation plate
(Attached to the rear of the indoor unit)
Wireless remote control
Remote contorol holder
Tapping screws
(for installation board 4dia. by 25mm)
Wood screw
(for remote contorol switch holder 3.5dia. by 16mm)
Baterry [R03 (AAA, Micro) 1.5V]
Option parts
e S
i l a
g n
p
a l
e t
l S
e e
e v
n I
l c
n i
i t a
n o
p
a l
e t
P
t u
y t
Drain hose (extention hose)
Piping cover
(for insulation of connection piping)

Selection of installation location

(Install at location that meets the following conditions, after getting approval from the customer)
INDOOR UNIT
Where there is no obstructions to the air flow and where
the cooled air can be evenly distributed.
A solid place where the unit or the wall will not vibrate.
A place where there will be enough space for servicing.
(Where space mentioned right can be secured)
Where wiring and the piping work will be easy to con-
duct.
The place where receiving part is not exposed to the di-
rect rays of the sun or the strong rays of the street light-
ing.
A place where it can be easily drained.
A place separated at least 1m away from the television or
the radio.
(To prevent interfence to images and sounds.)
A place that home appliance and household goods, etc.
aren't below unit.
Avoid installing this unit in place where there is much oil
mist.
Places where there is no electric equipment or household
under the installing unit.
Wireless remote control
A place where the air conditioner can be received the sig-
nal surely during operating the wireless remote control.
Places where there is no affected by the TV and radio etc.
Do not place where exposed to direct sunlight or near
heat devices such as a stove.
Necessary tools for the installation work
Q'ty
1
Plus headed driver (Phillips screwdriver)
2
Knife
1
3
Saw
1
4
Tape measure
1
5
Hammer
4
6
Spanner wrench
7
Torque wrench
2
8
Hole core drill (65mm in diameter)
2
9
Wrench key (Hexagon) [4m/m]
Q'ty
10
Vacuum pump
1
Vacuum pump adapter
11
(Anti-reverse flow type)
1
12
Gauge manifold
1
13
Change hose
1
14
Flaring tool set
1
15
Gas leak detector
1
Gauge for projection adjustment (Used when flare
16
is made by using conventional flare tool)
17
Pipe bender
CAUTION
Completely seal the hole
on the wall with putty.
Otherwise, furniture, or
other, may be wetted by
leaked water or dewing.

-
-
(
)
14.0 ~ 82.0N · m
(1.4 ~ 8.2kgf · m)
(
Designed specifically
for R22
(
)
Designed specifically
for R22
(
)
Designed specifically
for R22
(
)
Designed specifically
for R22
(
)
Designed specifically
for R22
10 cm minimum from the ceiling
Sleeve
(sold separately)
Wireless remote control
Remote control holder
Wood screws
Indoor side
Outdoor side
putty
putty
'12 • SRK-T-125
)
Installation plate

Hide quick links: