5 Maintenance and service
Tips about DHW tank temperature
▪ Make sure the number (available hot water for x persons) on the
DHW tank temperature home page is NOT higher than your actual
needs.
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program  to  heat  up  the  DHW  tank  to  a  preset  value  (Storage
comfort  =  higher  DHW  tank  temperature)  during  the  night,
because then space heating demand is lower and electric tariffs
may be lower.
▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,
program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.
▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.
Example: After installation, lower the DHW tank temperature daily
by 1°C and check if you still have enough hot water.
▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during
periods of the day when instant hot water is necessary. Example:
In the morning and evening.
5
Maintenance and service
5.1
Overview: Maintenance and
service
The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.
As end user, you have to:
▪ Keep the user interface clean with a soft damp cloth. Do NOT use
any detergents.
▪ Regularly check if the water pressure indicated on the manometer
is above 1 bar.
Refrigerant
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol. Do NOT vent gases into the atmosphere.
Refrigerant type: R410A
Global warming potential value: 1975
Periodical  inspections  for  refrigerant  leaks  may  be  required
depending on the applicable legislation. Please contact your installer
for more information.
5.2
To find the contact/helpdesk
number
Go to [6.3.2]: 
 > Information > Error handling > Contact/helpdesk
number.
Operation manual
8
6

Troubleshooting

6.1
Symptom: You are feeling too cold
(hot) in your living room
Possible cause
The desired room temperature is
too low (high).
The desired room temperature
cannot be reached.
6.2
Symptom: The water at the tap is
too cold
Possible cause
You ran out of domestic hot
water because of unusual high
consumption.
The desired DHW tank
temperature is too low.
Corrective action
Increase (decrease) the desired
room temperature.
If the problem recurs daily, do
one of the following:
▪ Increase  (decrease)  the  room
temperature preset value.
▪ Adjust  the  room  temperature
schedule.
Increase the desired leaving
water temperature in accordance
with the heat emitter type.
Corrective action
If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.
If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.
If the problems recurs daily, do
one of the following:
▪ Increase 
the 
DHW 
temperature preset value.
▪ Adjust 
the 
DHW 
temperature 
schedule.
Example: 
Program 
additionally 
heat 
up 
DHW  tank  to  a  preset  value
(Storage  eco  =  lower  tank
temperature) during the day.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351750­1C – 2014.03