Time server IP address
The camera can receive the time signal from a time server using various time server protocols,
and then use it to set the internal clock. The unit polls the time signal automatically once every
minute.
Enter the IP address of a time server here.
Time server type
Select the protocol that is supported by the selected time server. Preferably, you should
select the SNTP server as the protocol. This supports a high level of accuracy and is required
for special applications and subsequent function extensions.
Select Time server for a time server that works with the protocol RFC 868.
4.4

Display Stamping

Various overlays or "stamps" in the video image provide important supplementary information.
These overlays can be enabled individually and are arranged on the image in a clear manner.
After you set all necessary parameters, click the View Control link to see how the stamping
appears on the LIVE page.
Camera name stamping
This field sets the position of the camera name overlay. It can be displayed at the Top, at the
Bottom or at a position of your choice that you can then specify using the Custom option. Or
it can be set to Off for no overlay information.
1.
2.
3.
Logo
Click Choose File to select a file. Heed the restrictions for file format, logo size, and color
depth. Click Upload to load the file to the camera.
If no logo is selected, Configuration displays the message, "No file chosen."
Logo position
Select the position for the logo on the OSD: Left or Right.
Select Off (the default value) to disable logo positioning.
Time stamping
This field sets the position of the time overlay. It can be displayed at the Top, at the Bottom or
at a position of your choice that you can then specify using the Custom option. Or it can be
set to Off for no overlay information.
1.
2.
3.
Display milliseconds
If necessary, you can also display milliseconds. This information can be useful for recorded
video images; however, it does increase the processor's computing time. Select Off if you do
not need to display milliseconds.
Bosch Security Systems
Select other values from the list fields below the table to change the entry. Changes are
made immediately.
If there are empty lines at the bottom of the table, for example after deletions, you can
add new data by marking the row and selecting required values from the list fields.
Now click the OK button to save and activate the table.
Select the desired option from the list.
If you select the Custom option, additional fields are displayed where you can specify the
exact position (Position (XY)).
In the Position (XY) fields, enter the values for the desired position.
Select the desired option from the list.
If you select the Custom option, additional fields are displayed where you can specify the
exact position (Position (XY)).
In the Position (XY) fields, enter the values for the desired position.