4-wire connection: Power supply cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through
the neutral
1. Remove the ground-link screw from the range frame.
Save the ground-link screw. Bend the ground link away
from the range so that it does not contact the range.
A
A. Ground-link screw
B. Ground link bent away from range
2. Connect the green ground wire from the power supply
cord to the range using the ground-link screw. The ground
wire must be attached first and must not contact any other
terminal.
3. Use a ¼" nut driver to remove the hex washer head screws
from the terminal blocks.
4. Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
D
C
B
A
A. Line 1
B. Green ground wire
C. Ground-link screw
D. Hex washer head screw
E. Silver-colored terminal
block screw
5. Connect the other 2 wires (lines 1 and 2) to the outer
aluminum terminal blocks.
6. Securely tighten screws for proper electrical connection.
7. Tighten strain-relief screws.
8. Replace terminal block cover.
14
B
E
F
G
H
I
F. Ground link
G. Neutral (center) wire
H. Line 2
I. UL listed strain relief and
40- or 50-amp range power
supply cord
3-wire connection: Power supply cord
Use this method only if local codes permit connecting
cabinet-ground conductor to neutral wire of power supply cord.
1. Use a ¼" nut driver and remove the hex washer head
screws from the aluminum terminal blocks.
2. Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
C
B
A
A. Line 1
B. Ground link
C. Hex washer head screw
D. Silver-colored terminal
block screw
3. Connect the other 2 wires (lines 1 and 2) to the outer
terminal screws on the terminal block.
4. Tighten strain-relief screws.
5. Replace terminal block cover.

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Assemble flexible connector from gas supply pipe to
pressure regulator located in the middle rear of the range.
2. Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters.
(See B and G in the following illustration.)
D
E
F
G
E. Neutral (center) wire
F. Line 2
G. UL listed strain relief and
40- or 50-amp range power
supply cord