Low-Voltage Power Unit - Oki C9500 Maintenance Manual

Color led page printer
Hide thumbs Also See for C9500:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL

2.3.35 Low-voltage Power Unit

(1) Remove the Printer Unit Chassis. (See Sec. 2.3.24.)
(2) Unplug the connector 1.
(3) Unscrew 6 screws 2 and remove Low-voltage Power Unit 5.
(4) Unplug the connector 3.
(5) Unscrew the screw 6, release the claw at the AC Switch 7 and remove the plate 8.
(6) Unscrew the screws 9 and 0, and remove the AC Inlet A from the plate B.
2
8
7
1
6
3
2
5
2
0
0
0
B
A
9
Figure 2-3-35 Low-voltage Power Unit