TO SET - END PRESSURE ALARM

(while in the Surface Mode)
Factory set for 00 PSI/BAR (disabled), the End Pressure
Alarm can be set to values between 300 and 1500 PSI (20
to 104 BAR) in increments of 100 PSI (7 BAR).
• Press Both buttons simultaneously, release when SET: 2
appears (4 seconds).
• Press and release the Left (Advance) button, the Units
screen appears with the set point flashing.
• Press the Left (Advance) button 11 more times.
• The graphic End and Alarm (speaker) icon appear with
the End Pressure Alarm value flashing (Fig. 35).
• Press and hold the Right (Select) button to scroll through
the Alarm values in increments of 100 PSI (6 BAR).
• Press the Left (Advance) button to accept the setting and
advance to Set Dive Time Remaining Alarm, or press and
hold Both buttons for 2 seconds to revert to Surface
Mode.