TO SET - ELAPSED DIVE TIME ALARM

(while in the Surface Mode)
Factory set for 3:00 (hr:min), the Alarm can be set to values
between 0:10 and 3:00 (hr:min) in increments of 5 minutes.
• Press Both buttons simultaneously, release when SET: 1
appears (2 seconds).
• Press and release the Left (Advance) button, FO2 ap-
pears with the set point value flashing.
• Press the Left (Advance) button 2 more times.
• The graphic EdT, and Alarm and Dive Time icons appear
with the Elapsed Dive Time value flashing (Fig. 22).
• Press and release the Right (Select) button until the
desired Alarm value appears; or press and hold to scroll
through the set points.
• Press the Left (Advance) button to accept the setting and
advance to PC Interface, or press and hold Both buttons
for 2 seconds to revert to Surface Mode.
N
2
O
2
ATR