3. INSTALLATION METHOD

a. General
1
Detection range and installation height.
Maximum distances between Receiver and Transmitter are listed below.
AX-250PLUS = 250ft (75m) Max
AX-500PLUS = 500ft (150m) Max
AX-350TF = 350ft (100m) Max
AX-650TF = 650ft (200m) Max
and the installation height should be at 27"~40". (0.7~1m)
2
Alignment angle
3
Pole mounting
* Pole size should be as follews: 1 3/8"~1 7/8" O.D (Ф34~Ф48mm)
(Standard U.S. 1 1/4" or 1 1/2" pipe.)
* The length of the wiring cable out of the pole should be within 20
inches (60cm).
* Face transmitter and receiver towards each other when pole mounting.
NOTE
Pole Mount Back Cover
Electric Box Mounting
For connections to single gang
electric boxes, follow intructions for
wall mounting.
1. Maximum torque requires to tighten the conduit shall not exceed 150 lb-in.
2. The conduit shall be bended before installing into the detector unit.
3. Excessive pulling of the conduit downward may cause slight cracking to the plastic conduit fitting.
b. Installation Method
1
Lossen the cover lock screw and remove the front cover. And loosen the
unit base mounting screw and remove mounting plate by sliding it down
against the unit base.
2
well mounting
Pole mounting
P l a c e U - S h a p e b r a c k e t s
at the top of the pole. And
pull out the wire through the
Pull out the wire through the
wiring hole og the Mounting
wiring hole on the mounting
plate, attach the mouting
plate and attach the plate to
plate to the U-Shape bracket
the well with the screw.
with screw.
3
* C o n n e c t w i r e t o t h e t e r m i n a l s
(See Sec. 4-1, 5-1 "Terminal").
Conduit Installtion
Conduit can be installed directly into the bottom of the unit by removihg the
knockout on the bottom of the cover.
3
Two unit installation
(back to back)
Fix two U-shape brackets in
layers on a pole, two units
can be installed back to back
on a pole at the same height.
* After checking optical alignment
and operation check (See Sec. 4
-3, 5-3 OPTICAL ALIGNMENT),
r e p l a c e t h e c o v e r, a n d f a s t e n
the lock screw tightly.