3.8.3 Digital EXtra Device Port (Digital XDP) Connection
Using an EXtra Device Port
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Back View of DPTs
TO TEL
TO MAIN UNIT
/ PABX
128
Installation Manual
Master DPT
Cable
Maximum Distance
26 AWG: 30 m (98 ft)
24 AWG: 50 m (164 ft)
22 AWG: 60 m (196 ft)
CAT 5:
50 m (164 ft)
Master DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "T", "R",
2-conductor wiring cord
"D1" and "D2".
Connect pins "T" and "R".
Slave DPT
Slave DPT
To SLT
SLT
TO MAIN UNIT
/ PABX
TO TEL