Installation
The Colorist™
Line 12Qa must
be linked using
DMX cable in a
daisy chain (serial)
fashion. To comply with
the EIA-485 standard, no
more than 32 products
should be connected on
one daisy chain without
using a DMX optically
isolated splitter. Doing
otherwise may result in
deterioration of the digital
DMX signal.
USITT
recommends
limiting the total
length of the DMX cable
(from the first product/
controller to the last
product) to 300–455 m
(985–1,500 ft).
To connnect the
Colorist™ Line
12Qa to your
DMX network, it
is necessary to use the
3-pin to 5-pin adapters
supplied with this product.
When not using
the Power
Output, DMX
Input or DMX Output
connectors, you must seal
the cable ends with the
supplied caps.
8
DMX Linking
You may link the Colorist™ Line 12Qa to a DMX controller using a standard DMX serial
connection. If using other DMX products compatible with the Colorist™ Line 12Qa, you can
control each individually with a single DMX controller.
If you are not familiar with the DMX standard, or if you need information about the DMX
cables needed to link the Colorist™ Line 12Qa to a DMX controller, you may
download
the
"DMX
http://www.iluminarc.com/reports/dmx-primer.
DMX Connection
The Colorist™ Line 12Qa uses a regular DMX data connection for its DMX personalities:
4-CH, 6-CH, 10CH, 48CH, and 53CH.
IP65 DMX Cable Table
Connection
Ground
Data -
Data +
IP65 DMX Connector Pins
Male
Primer"
from
the
DMX (U.S.)
DMX (Europe)
Shield
White
Red
ILUMINARC®
website
IP65 Pin
Shield
Blue
Brown
Female