Page 2
Document Revision The Ilumipod Inground IP Series User Manual Rev. 01f supersedes all previous versions of this manual. Please discard any older versions of this manual you may have, whether in printed or electronic format, and replace them with this version.
ARC 1 ..........................15 ARC 1 + D ......................... 15 ARC FULL ......................... 15 SPECIAL 1 ........................16 VW ............................. 16 VW + D ..........................16 Ilumipod Inground IP Series User Manual (Rev. 02 )
Page 4
Contact Us ........................26 Technical Specifications ..................... 27 Ilumipod Inground 36 IP VW ....................27 Ilumipod Inground 36 IP RGB .................... 28 Ilumipod Inground Tri-12 IP ....................29 Ilumipod Inground IP Series User Manual (Rev. 02)
This icon Unpacking Instructions indicates important Immediately upon receiving a product from ILUMINARC®, carefully unpack the carton. installation or Check the contents of the box to ensure that all parts are present and that they are in good configuration information.
Ilumipod In case of a serious operating problem, stop using this product immediately! Inground IP product may require service, please ® contact ILUMINARC Technical Support. Ilumipod Inground IP Series User Manual (Rev. 02 )
Product Description 2. Product Description The Ilumipod Inground IP Series includes three separate products: Ilumipod Inground 36 IP RGB, Ilumipod Inground 36 IP VW, and Ilumipod Inground Tri-12 IP. Common Features Remotely addressable DMX-512 LED inground wash light IP67 ingress protection...
This helps to distribute the load uniformly over the support a distributed load of up to product’s surface and avoids creating dangerous bumps. 3,000 kg (6,614 lbs) when properly installed. Ilumipod Inground IP Series User Manual (Rev. 02)
12. Tighten the nuts uniformly by alternating between opposite nuts. 13. Reattach the product to the installation sleeve by turning the Allen bolts clockwise. You should only need a turn or two to have the stainless steel collar firmly attached. Ilumipod Inground IP Series User Manual (Rev. 02 )
Input Voltage and Frequency IP product to a power line with the proper voltage The products in the Ilumipod Inground IP Series have an auto-ranging power supply with an and frequency, as per the input voltage range of 100~240 VAC, 50/60 Hz.
IP67 rated. Signal Distribution Connect the bare-ended signal cable from the product to a signal distribution box as indicated below. (Black) Ilumipod Inground IP Series User Manual (Rev. 02 )
Installation Controllers The products in the Ilumipod Inground IP Series can operate with a standard DMX controller, the ILUMICON controller, or the Ilumicode controller. The sections below will show you how to connect these products to the corresponding controllers. The instructions to operate these products with each of the above controllers are in the Operation chapter of this manual.
20 products in this mode and keep the total distance to less than 60 m (197 ft). Otherwise, you might need to use an optically isolated signal amplifier. Ilumipod Inground IP Series User Manual (Rev. 02 )
30 seconds of inactivity. Menu Map The products in the Ilumipod Inground IP Series have distinct menu maps based on the colors they produce, whether RGB or White. The Ilumicode controller presents the functions for both types of products.
RGB only output products. If you scroll after STRB, you will see the AMBE, COOL and WARM colors. Just skip them as they do not work with the RGB products. Ilumipod Inground IP Series User Manual (Rev. 02 )
1. Go to DIMMER. 2. Select a dimmer curve (OFF or DIM1~4). DIMMER Description Dimmer curve is linear with fader Non-linear (fastest) DIM1 DIM2 Non-linear (fast) Non-linear (slow) DIM3 DIM4 Non-linear (slowest) Ilumipod Inground IP Series User Manual (Rev. 02)
Reset (Only for 36 IP RGB and Tri-12 IP) 1. Go to SETTINGS > RESET TO FACTORY SETTINGS. 2. Select an option (YES/NO). Ilumipod Inground IP Series User Manual (Rev. 02 )
Troubleshooting Table as a guide Technical Support. only. In most cases, opening the product’s housing will invalidate its warranty, unless there is a written indication to the contrary. Ilumipod Inground IP Series User Manual (Rev. 02)
DMX signal problems Install an optically coupled DMX splitter Too many products after unit #32 or before Keep DMX cables separated from power Interference from AC wires cables or fluorescent/black lights Ilumipod Inground IP Series User Manual (Rev. 02 )
Technical Information Exploded View Reference Description Stainless steel cover 15 mm tempered glass Diaphragm LED lens panels LED boards Heat sink Power supply Control board Inner housing Installation sleeve Dustproof board Ilumipod Inground IP Series User Manual (Rev. 02)
Pro 1.3.2 copyright 2003- 907.01 2008 by 226.75 jSolutions, Inc. Reported data calculated 100.78 from manufacturer's data 56.69 file, based on IES recommended methods 32.28 25.19 Vertical Spread 13.4º Horizontal Spread 13.1º Ilumipod Inground IP Series User Manual (Rev. 02 )
Photometrics Pro 1.3.2 98.18 copyright 2003- 43.63 2008 by jSolutions, Inc. 24.54 Reported data calculated 15.71 from manufacturer's data 10.91 file, based on IES recommended methods Vertical Spread 26.6º Horizontal Spread 26.5º Ilumipod Inground IP Series User Manual (Rev. 02)
226.75 Photometrics Pro 100.78 1.3.2 copyright 56.69 2003-2008 by jSolutions, Inc. 36.28 Reported data calculated 25.19 from manufacturer's data Vertical Spread 13.4º Horizontal Spread 13.1º file, based on IES recommended methods Ilumipod Inground IP Series User Manual (Rev. 02 )
277.84 Pro 1.3.2 69.46 copyright 2003- 2008 by 30.87 jSolutions, Inc. 17.36 Reported data calculated 11.11 from manufacturer's data file, based on IES 7.72 recommended methods Vertical Spread 28.4º Horizontal Spread 28.3º Ilumipod Inground IP Series User Manual (Rev. 02)
Pro 1.3.2 156.49 copyright 2003- 69.55 2008 by jSolutions, Inc. 39.12 Reported data calculated 25.04 from manufacturer's data 17.39 file, based on IES recommended methods Vertical Spread 18.4º Horizontal Spread 18.3º Ilumipod Inground IP Series User Manual (Rev. 02 )
LED. Data from the manufacturer of the LED are not independently verified or measured by ILUMINARC®. When the product is operating in optimal environmental conditions, the LED lifetime is rated to be 50,000 to 70,000 hours by the LED manufacturer.
® damage report and any related claims with the carrier, not ILUMINARC . The customer must submit the report upon reception of the damaged merchandise. Failure to do so in a timely Always keep the manner may invalidate the customer’s claim with the carrier.
DMX Channels ........................1, 2, or 3 Ordering Information Ilumipod Inground 36 IP Optic 15º VW ................11036010 Ilumipod Inground 36 IP Optic 30º VW ................11036008 Warranty Information Warranty ....................... 2-year limited warranty Ilumipod Inground IP Series User Manual (Rev. 02)
DMX Channels ......................1, 3, 4, 6, or 7 Ordering Information Ilumipod Inground 36 IP Optic 15º RGB................11036009 Ilumipod Inground 36 IP Optic 30º RGB................11036007 Warranty Information Warranty ....................... 2-year limited warranty Ilumipod Inground IP Series User Manual (Rev. 02 )