Iluminarc IP Series User Manual

Iluminarc IP Series User Manual

Ilumipod inground ip series

Advertisement

Quick Links

I
l
u
m
i
p
o
d
I
n
g
r
o
u
n
d
I
P
S
e
r
i
e
s
I
l
u
m
i
p
o
d
I
n
g
r
o
u
n
d
I
P
S
e
r
i
e
s
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Iluminarc IP Series

  • Page 1 User Manual...
  • Page 2 Document Revision The Ilumipod Inground IP Series User Manual Rev. 01f supersedes all previous versions of this manual. Please discard any older versions of this manual you may have, whether in printed or electronic format, and replace them with this version.
  • Page 3: Table Of Contents

    ARC 1 ..........................15   ARC 1 + D ......................... 15   ARC FULL ......................... 15   SPECIAL 1 ........................16   VW ............................. 16   VW + D ..........................16 Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 4 Contact Us ........................26   Technical Specifications ..................... 27   Ilumipod Inground 36 IP VW ....................27   Ilumipod Inground 36 IP RGB .................... 28   Ilumipod Inground Tri-12 IP ....................29 Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 5: Introduction

    This icon Unpacking Instructions indicates important Immediately upon receiving a product from ILUMINARC®, carefully unpack the carton. installation or Check the contents of the box to ensure that all parts are present and that they are in good configuration information.
  • Page 6: Safety Notes

    Ilumipod  In case of a serious operating problem, stop using this product immediately! Inground IP product may require service, please ® contact ILUMINARC Technical Support. Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 7: Product Description

    Product Description 2. Product Description The Ilumipod Inground IP Series includes three separate products: Ilumipod Inground 36 IP RGB, Ilumipod Inground 36 IP VW, and Ilumipod Inground Tri-12 IP. Common Features  Remotely addressable DMX-512 LED inground wash light  IP67 ingress protection...
  • Page 8: Product Dimensions

    Product Description Product Dimensions (All Ilumipod Inground IP Series models) Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 9: Installation

    This helps to distribute the load uniformly over the support a distributed load of up to product’s surface and avoids creating dangerous bumps. 3,000 kg (6,614 lbs) when properly installed. Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 10: Beam Angle Adjustment

    12. Tighten the nuts uniformly by alternating between opposite nuts. 13. Reattach the product to the installation sleeve by turning the Allen bolts clockwise. You should only need a turn or two to have the stainless steel collar firmly attached. Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 11: Ac Power

    Input Voltage and Frequency IP product to a power line with the proper voltage The products in the Ilumipod Inground IP Series have an auto-ranging power supply with an and frequency, as per the input voltage range of 100~240 VAC, 50/60 Hz.
  • Page 12: Signal Wiring

    IP67 rated. Signal Distribution Connect the bare-ended signal cable from the product to a signal distribution box as indicated below. (Black) Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 13: Controllers

    Installation Controllers The products in the Ilumipod Inground IP Series can operate with a standard DMX controller, the ILUMICON controller, or the Ilumicode controller. The sections below will show you how to connect these products to the corresponding controllers. The instructions to operate these products with each of the above controllers are in the Operation chapter of this manual.
  • Page 14: Ilumicode

    20 products in this mode and keep the total distance to less than 60 m (197 ft). Otherwise, you might need to use an optically isolated signal amplifier. Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 15: Operation

    30 seconds of inactivity. Menu Map The products in the Ilumipod Inground IP Series have distinct menu maps based on the colors they produce, whether RGB or White. The Ilumicode controller presents the functions for both types of products.
  • Page 16: Rgb Functions Menu Map

    RGB only output products. If you scroll after STRB, you will see the AMBE, COOL and WARM colors. Just skip them as they do not work with the RGB products. Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 17: Programming

    1. Go to DIMMER. 2. Select a dimmer curve (OFF or DIM1~4). DIMMER Description Dimmer curve is linear with fader Non-linear (fastest) DIM1 DIM2 Non-linear (fast) Non-linear (slow) DIM3 DIM4 Non-linear (slowest) Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 18: Ilumicon Control

    Reset (Only for 36 IP RGB and Tri-12 IP) 1. Go to SETTINGS > RESET TO FACTORY SETTINGS. 2. Select an option (YES/NO). Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 19: Dmx Values

    Dimmer is set by Ilumicode 010  029 OFF (Dimmer is linear) 030  069 DIM1 (Fastest dimmer curve) Dimming Speed 070  129 DIM2 130  189 DIM3 190  255 DIM4 (Slowest dimmer curve) Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 20: Special 1

    000  255 0 ~ 100% Dimmer 000  255 0 ~ 100% Warm White 000  255 0 ~ 100% Cool White SOLID Channel Function Value Percent/Setting 000  255 0 ~ 100% Dimmer Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 21: Technical Information

    Troubleshooting Table as a guide Technical Support. only. In most cases, opening the product’s housing will invalidate its warranty, unless there is a written indication to the contrary. Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 22: Troubleshooting Guide

    DMX signal problems Install an optically coupled DMX splitter Too many products after unit #32 or before Keep DMX cables separated from power Interference from AC wires cables or fluorescent/black lights Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 23: Exploded View

    Technical Information Exploded View Reference Description Stainless steel cover 15 mm tempered glass Diaphragm LED lens panels LED boards Heat sink Power supply Control board Inner housing Installation sleeve Dustproof board Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 24: Photometrics

    Pro 1.3.2 copyright 2003- 907.01 2008 by 226.75 jSolutions, Inc. Reported data calculated 100.78 from manufacturer's data 56.69 file, based on IES recommended methods 32.28 25.19 Vertical Spread 13.4º Horizontal Spread 13.1º Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 25: Ilumipod Inground 36 Ip 30º Vw

    Photometrics Pro 1.3.2 98.18 copyright 2003- 43.63 2008 by jSolutions, Inc. 24.54 Reported data calculated 15.71 from manufacturer's data 10.91 file, based on IES recommended methods Vertical Spread 26.6º Horizontal Spread 26.5º Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 26: Ilumipod Inground 36 Ip 15º Rgb

    226.75 Photometrics Pro 100.78 1.3.2 copyright 56.69 2003-2008 by jSolutions, Inc. 36.28 Reported data calculated 25.19 from manufacturer's data Vertical Spread 13.4º Horizontal Spread 13.1º file, based on IES recommended methods Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 27: Ilumipod Inground 36 Ip 30º Rgb

    277.84 Pro 1.3.2 69.46 copyright 2003- 2008 by 30.87 jSolutions, Inc. 17.36 Reported data calculated 11.11 from manufacturer's data file, based on IES 7.72 recommended methods Vertical Spread 28.4º Horizontal Spread 28.3º Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 28: Ilumipod Inground Tri-12 Ip 16º

    Pro 1.3.2 156.49 copyright 2003- 69.55 2008 by jSolutions, Inc. 39.12 Reported data calculated 25.04 from manufacturer's data 17.39 file, based on IES recommended methods Vertical Spread 18.4º Horizontal Spread 18.3º Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 29: Led Disclaimer

    LED. Data from the manufacturer of the LED are not independently verified or measured by ILUMINARC®. When the product is operating in optimal environmental conditions, the LED lifetime is rated to be 50,000 to 70,000 hours by the LED manufacturer.
  • Page 30: Returns Procedure

    ® damage report and any related claims with the carrier, not ILUMINARC . The customer must submit the report upon reception of the damaged merchandise. Failure to do so in a timely Always keep the manner may invalidate the customer’s claim with the carrier.
  • Page 31: Technical Specifications

    DMX Channels ........................1, 2, or 3 Ordering Information Ilumipod Inground 36 IP Optic 15º VW ................11036010 Ilumipod Inground 36 IP Optic 30º VW ................11036008 Warranty Information Warranty ....................... 2-year limited warranty Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 32: Ilumipod Inground 36 Ip Rgb

    DMX Channels ......................1, 3, 4, 6, or 7 Ordering Information Ilumipod Inground 36 IP Optic 15º RGB................11036009 Ilumipod Inground 36 IP Optic 30º RGB................11036007 Warranty Information Warranty ....................... 2-year limited warranty Ilumipod Inground IP Series User Manual (Rev. 02 )
  • Page 33: Ilumipod Inground Tri-12 Ip

    Data pin configuration ..............Pin 1 shield, pin 2 (-), pin 3 (+) Protocols ......................USITT DMX512-A DMX Channels ......................1, 3, 4, 6, or 7 Ordering Information Ilumipod Inground Tri-12 IP Optic 15º ................11012001 Warranty Information Warranty ....................... 2-year limited warranty Ilumipod Inground IP Series User Manual (Rev. 02)
  • Page 34 ® ILUMINARC 5200 NW 108 Avenue Sunrise, FL 33351 U.S.A. Tel.: (954) 929-1115 FAX: (954) 929-5560 www.iluminarc.com Ilumipod Inground IP Series User Manual Rev. 02 August 2011...