Fueling Your Heater; To Start Heater; To Shutdown Heater; To Restart Heater - L.B. White CP045DK Owner's Manual And Instructions

Table of Contents

Advertisement

FUELING YOUR HEATER

tank outdoors.
WARNING
Fire and explosion hazard!
still hot.
IMPORTANT : REGARDING FIRST IGNITION OF
be done OUTDOORS. This allows the oils, etc., used
in manufacturing heater to be burned off outside.

TO START HEATER

1. Fill fuel tank with kerosene or No. 1 fuel oil.
2. Attach fuel cap.
3. Plug power cord into three prong, grounded extension
cord. Extension cord must be at least six feet long.
- Extension Cord Wire Size Requirements:
- 6 to 100 feet (1.8 to 30.53 meters) long, use 16
AWG conductor.
- 101 to 200 feet (30.8 to 61 meters) long, use 14
AWG conductor.
NO THERMOSTAT ON 45
4. Turn thermostat control knob to desired setting and
push power switch to "ON" position. Power lamp will
light and heater will start.
NOTE: Room Temp. display indicates as following:
- When room temp. is less than 0
- When room temp. is between 0
"Temp. is Displayed"
-
W
h
e
n
r
o o
m
e t
m
p
If heater does not start, the thermostat setting
may be too low. Turn THERMOSTAT CONTROL
KNOB to higher position to start heater. If heater
still does not start, turn power switch to "OFF"
and then to "ON" position (See Figure 7.1 &7.2)
If heater still does not start, see Troubleshooting
on page 18.
NOTE: The major electrical components of this
heater are protected by a safety fuse mounted to
the PCB board. If your heater fails to start, check
should also check your power source to insure
that proper voltage and frequency are being
supplied to the heater.
: "lo".
ºF
and 99
ºF
s i
g
e r
t a
r e
h t
a
n
9
9
: "Hi"
ºF
TO SHUT DOWN HEATER
Turn switch to "OFF" and unplug power cord.
Model CP045DK
Lamp
Power/Reset Switch
Figure 7.1 - Controls
Model CP125EK, CP175EK, CP210EK
Lamp
Room T emp. Displa y
Thermostat
Control Knob
Figure 7.1 - Controls

TO RESTART HEATER

1. Wait 10 seconds after stopping heater.
2. Repeat steps under, "TO START HEATER."
PIGGYBACK POWER CORD
:
ºF
Figure 7.2 - Controls
• Always cover electric outlet when not in use.
Don't plug and use an appliance of more than
5A current in this outlet.
OPERATION (cont.)
Model CP075DK
Lamp
Power/Reset
Switch
Thermostat Cont rol Knob
Power/Reset
Switch
Cover
Electric Outlet
WARNING
SHOCK HAZARD!
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp175ekCp075dkCp210ekCp125ek