Methods of Extraction
The very best method of clearing the kitchen of unwanted odours is by connecting the appliance to an
exhaust duct and venting to the outside atmosphere via the ceiling or an exterior wall. (Suitable ducting kits
may be purchased from the depot where you bought the extractor.) You do not need charcoal filters when
using the external ducting mode.
Fig 1.
Ducting mode
(No charcoal filters required)
Extraction Via Ducting
Never use the hood in areas where devices with
exhaust pipes connected to the outside are
already operating unless perfect ventilation can be
guaranteed.
Connect the external ducting kit to the outlet
of the extractor.
Charcoal filters are not required if the extractor
is to be ducted out.
Page _ 8
Vent through external
wall or ceiling
Ducting kit (APL2805/6/7)
Supplied Separately
Fig 2.
Recirculation mode
(Charcoal filters HJA2911 required)
Extraction Via Recirculation
For extraction via recirculation, attach 2 charcoal
filters to the sides of the motor inside the hood.
Thease can be orderd seperatly quoting part
reference HJA2911
Before attempting to change or fit the
charcoal filters ensure power to the extractor is
switched off.
Remove the grease filters
Align the carbon filters over the pins located
on either side of the fan motor.
Turn the carbon gently, until you feel them
click into postilion.
Replace the grease filters before the power
supply it turned back on.
www.howdens.com
Filtered air
recirculated