Replacement Of The Electronic Control Block; Replacement Of The Plug Or Flame Sensor; Replacement Of Micro Switch (Water Flow Sensor) - BaltGaz LUX User Manual

Table of Contents

Advertisement

13.14 Replacement of the electronic control block

13.14.1 Remove the casing, see p. 13.1
13.14.2 Disconnect all external connection cables and connectors of the electronic control block 4.
13.14.3Screw off the screw connecting the electronic control block 4 to the carrier 36 and remove the block, pushing up the lock on the left side of the
block under the carrier.
13.14.4 Install a new electronic control block.
13.14.5 Check the appliance's operation with the new electronic control block .

13.15 Replacement of the plug or flame sensor

13.15.1 Remove the casing, see p 13.1.
13.15.2 Remove the cables from the plug and from the flame sensor of the ignition burner 11.
13.15.3 Remove the flame sensor and (or) the plug from the ignition burner 11, unscrewing its fixation screws.
13.15.4 Install a new flame sensor and/or plug
13.15.5 Check the appliance's working capacity.

13.16 Replacement of micro switch (water flow sensor)

13.16.1 Remove the casing, see p 13.1.
13.16.2 Remove the cables from the micro switch 16.
13.16.3 Unscrew two screws fixing the micro switch 16 to the carrier and remove it.
13.16.4 Install a new micro switch.
13.16.5 Check the appliance's operation with the new micro switch.

Advertisement

Table of Contents
loading

Table of Contents