7.7.Connecting the appliance to the exhaust flue

7.7.1. In order to remove all gas combustion products and to ensure safe operation of the appliance the
following requirements to the exhaust flue and flue pipe, connecting the exhaust flue with the appliance
should be fulfilled:
- the exhaust flue should be air-tight and resistant to the heating load and impact of combustion products
It is not allowed to use ventilation channels to remove the combustion products;
- Draught in the exhaust flue should vary from 1,96 up to 29,40 Pа (see table 1 page 4);
- Flue pipe's material should be corrosion- resistant, nonflammable and sustain durable operation at the
temperature up to 200 С. The recommended materials are: stainless steel, zinc-plated and enameled steel,
aluminum, copper with wall thickness at least 0,5 mm;
- The flue pipe must have an inner diameter not less than 110 mm;
-Length of the vertical part of the flue pipe from the appliance must be at least 500 mm;
-Length of the flue pipe from the vertical part to the exhaust flue must be not more than 2 m;
- The flue pipe should have a slope of not less than 2 up in the direction of the link-up point with the
exhaust flue and minimal number of turns (not more than three)
- The flue pipe and its connection with the appliance must be air-tight; connecting the pipe with the
-
appliance should be performed in accordance with the scheme 7.