7.1.5
The appliance must be installed on the fire resistant walls:
brick, concrete (with a ceramic plating or without it).).
It is acceptable to install the appliance on firehard walls if the wall is insulated
with a zinc-coated steel sheet with thickness 0, 8...1 mm along the basalt felt
woolen board with thickness 3...5 mm. Insulation of the wall should go over
the overall dimensions of the appliance's body frame for at least 100 mm from
each side (see scheme 5).
The distance from the appliance's lateral surfaces to firehard walls without
insulation should be at least 250 mm. If the indicated distance is reduced to 150
mm, it is necessary to install the heat insulation (upholstery of walls by the
zinc-coated steel sheet on the sheet of the heat insulation material).
When installing the appliance on fire resistance walls it is not needed to install
the insulation.
7.1.6 It is forbidden to install the appliance on wooden walls; plastered walls which have wooden base;
on walls covered with highly flammable materials.
7.1.7 It is forbidden to install the appliance above a source of heat or open flame.
7.1.8. Place and height of the appliance's installation should meet the requirements of p .7.7 (page 14) of
this manual. Besides it is recommended to install the appliance on the height so that the viewing window will
be on the level of consumer's eyes or as close to this level as possible.
Also for effectuating the technical service at the appliance's installation it is necessary to keep the
following spaces:
The distance from the appliance's lateral surface to the lateral wall must be not less than 150 mm;
-
- Free space in front of the appliance's front surface should be not less than 600 mm.
7.1.9. Scheme of appliance's installation (connection) is represented on the scheme 6. It is recommended to
connect the appliance at first to the water supply system, to fill it with water and then connect it to the gas
network.
Scheme 6. Scheme of appliance's installation
17
Technical staff manual
Scheme 5. Appliance
installation on firehard walls