POSSIBLE FAILURES AND METHODS OF THEIR ELIMINATION

Failure
Error
code
No spark discharge
between the plug and
ignition burner before the
beginning of water flow
through the appliance
, the temperature indicator
is not glowing
Е0
The appliance switches
off.
температуры не
светится.
In 60 s after the spark
discharges begin the
Е1
electronic control block
does not detect the signal
from the flame sensor
Actuation of
electromagnetic valves
Е3
occurs before the
appearance of signal from
the water flow sensor.
The flame sensor transmits
a signal about flame
Е4
presence before the
appearance of signal from
the water flow sensor
The electronic control
Е5
block does not receive a
signal from the hot water
temperature sensor.
Failed seven-times attempt
to ignition (the ignition
burner ignites, than the
main burner ignites and
then in some seconds the
Е7
main burner's flame goes
out and the ignition
process repeats)
пламени до появления
сигнала от датчика
протока воды.
Table 6. Possible failures of the appliance «BaltGaz NEVALUX-6011»
Probable reason
Insufficient water consumption (less than 2,5 l/min) Increase water consumption.
There is no power element or it is discharged.
Incorrect power element installation.
The contacts or the connection circuit are
disrupted.
Water flow sensor is out of order.
Water unit is out of order (the membrane is
destroyed).
The electronic control block is out of order.
Appearance of soot deposit on the plug's electrode. Effectuate cleaning of the plug's electrode
Gas supply stop.
Presence of air in the gas pipelines.
The stop valve on the gas line by the inlet into the
appliance is closed or insufficiently opened.
аппаратом.
Absence or low pressure of gas in the duct.
The LPG reserve in the cylinder has expired
The connection of the electronic control block to
the flame sensor, the electromagnetic valve of the
ignition burner is disrupted.
The flame sensor is out of the zone of the ignition
burner's flame or its electrode touches the details
of the ignition or main burner.
Contamination of the nozzle or air inlet duct of the
ignition burner.
The electromagnetic valve of the ignition burner is
out of order.
The gap between the ignition plug and the nozzle
of the ignition burner is disrupted.
The high-voltage cable is put onto the ignition plug
not up to the stop (the spark goes to the burner's
manifold).
Appearance of soot deposit on the plug's electrode
or on the flame sensor's electrode
The electromagnetic valves are out of order.
The electronic control block is out of order .
An attempt to ignite the appliance from an
extraneous flame source.
The electronic control block is out of order.
The connection between the electronic control
block and the water temperature sensor is
disrupted.
Low gas pressure
The flame sensor is not in the zone of the main
burner's flame.
The electromagnetic valves are out of order
User's and technical staff manual
Install an operative power element
correctly
Check the connections and if necessary
clean up the contacts.*
Replace the water flow sensor.*
Repair or replace the water unit.*
Replace the electronic control block.*
from soot deposit.*
Address to the responsible gas facilities
service.
See p. 3.1.
Open the stop valve on the gas pipeline
completely.
Address to the responsible gas facilities
service.
Replace the LPG cylinder .
Check the connections, if necessary, clean
up the contacts or replace the cables.*
Adjust the flame sensor's position (its
electrode must be in the zone of the
ignition and main burners' flame and must
not touch the burners' details).*
Clean the ignition burner.*
Replace the valve (or the valve block).*
Install a gap of 4...5 mm between the
plug's electrode and the ignition burner's
nozzle.*
Put the high-voltage cable onto the
ignition plug up to the stop.*
Effectuate the cleaning of the plug's or the
flame sensor's electrode from soot
deposit.*
Replace the electromagnetic valve (or
valve block) that is out of order).*
Replace the electronic control block.*
Effectuate the appliance's ignition in
accordance with section 3.
Replace the electronic control block.*
Check the connection, replace the water
temperature sensor if necessary .*
Open the gas stop valve by the inlet into
the appliance completely.
Address to the responsible gas facilities
service.( or replace the LPG cylinder ).
Clean the gas filters.*
Adjust the flame sensor's position (its
electrode must be in the zone of the
ignition and main burner flames).*
Clean or replace the electromagnetic
valves.*
21
Methods of elimination